Section 3. local operation, Introduction, Standard operation – Xantrex Technology XPD 60-9 User Manual
Page 37: Operating modes and automatic crossover, Section 3, Local, Operation, Introduction standard operation

Release A
35
Section 3. Local Operation
Introduction
Once you have installed the power supply, it is ready to operate in local control mode
(that is, operation at the unit’s front panel).
•
See
for a brief explanation of Constant Voltage and
Constant Current Mode operation.
•
See
“Using Over Voltage Protection (OVP)” on page 38
,
, and
“Using Multiple Supplies” on page 40
on these topics.
•
See
, for troubleshooting information for the
operator.
•
Turn to
for descriptions of remote programming
options and remote monitoring of the supply.
Standard Operation
This power supply has two basic operating modes: Constant Voltage Mode and
Current Mode, and two control modes: Local Control Mode (default setting) and
Remote Programming Mode. Both operating modes are available regardless of
which control mode is used.
Operating
Modes and
Automatic
Crossover
The mode in which the power supply operates at any given time depends on the
combination of:
•
output voltage setting V
SET
•
output current limit setting I
SET
•
resistance of the attached load R
L
for a graphical representation of the relationships between these
variables.