TABLE 8:

ELECTRICAL DATA - 7-1/2 TON HP

Voltage

Compressors

OD

Fan

Motors

Supply Air

BLower

Motor FLA

Pwr

Exh

Motor Electric Heater

Model No.

Actual

Kw

Heater
Amps

Minimum Circuit

Ampacity (Amps)

MCA

with Power

Exhaust

(Amps)

Max Fuse

Size

*

(Amps)

Max Fuse Size

w/Pwr. Exh.*

(Amps)

RLA

ea

LRA

ea

FLA

ea

1.5 HP

(1.1 kW)

2 HP

(1.5 kW)

FLA

1.5 HP

(1.1 kW)

2 HP

(1.5 kW)

1.5 HP

(1.1 kW)

2 HP

(1.5 kW)

1.5 HP

(1.1 kW)

2 HP

(1.5 kW)

1.5 HP

(1.1 kW)

2 HP

(1.5 kW)

380

8.3

62

1.1

4.3

5.2

2.2

None

-

-

25.2

26.1

27.4

28.3

30

30

35

35

2TP04520950

5.6

8.5

35.8

36.7

38.0

38.9

40

40

40

45

2TP04521850

11.3

17.2

46.6

47.5

48.8

49.7

50

50

50

50

2TP04522450

15.0

22.8

53.7

54.6

55.9

56.8

60

60

60

60

2TP04523650

21.3

32.4

65.6

66.5

67.8

68.7

70

70

70

70

415

8.3

62

1.1

4.3

5.2

2.2

None

-

-

25.2

26.1

27.4

28.3

30

30

35

35

2TP04520950

6.7

9.3

36.8

37.7

39.0

39.9

40

40

40

45

2TP04521850

13.5

18.8

48.7

49.6

50.9

51.8

50

50

60

60

2TP04522450

17.9

24.9

56.3

57.2

58.5

59.4

60

60

60

60

2TP04523650

25.4

35.3

69.3

70.2

71.5

72.4

70

80

80

80

*.

Maximum HACR breaker of the same amp size is acceptable.

TABLE 9:

ELECTRICAL DATA - 10 TON HP

Voltage

Compressors

OD

Fan

Motors

Supply Air

BLower

Motor FLA

Pwr

Exh

Motor Electric Heater

Model No.

Actual

Kw

Heater
Amps

Minimum Circuit

Ampacity (Amps)

MCA

with Power

Exhaust

(Amps)

Max Fuse

Size

*

(Amps)

Max Fuse Size

w/Pwr. Exh.*

(Amps)

RLA

ea

LRA

ea

FLA

ea

2 HP

(1.5 kW)

4HP

(3 kW)

FLA

2 HP

(1.5 kW)

4 HP

(3 kW)

2 HP

(1.5 kW)

4 HP

(3 kW)

2 HP

(1.5 kW)

4 HP

(3 kW)

2 HP

(1.5 kW)

4 HP

(3 kW)

380

8.1

73.0

1.1

5.2

7.5

2.2

None

--

--

25.6

27.9

27.8

30.1

30

35

35

35

2TP04521850

11.3

17.2

47.1

49.4

49.3

51.6

50

50

50

60

2TP04522450

15.0

22.8

54.1

56.4

56.3

58.6

60

60

60

60

2TP04523650

21.3

32.4

66.1

68.4

68.3

70.6

70

70

70

80

2HP04535450

33.8

51.4

70.7

73.6

73.4

76.3

80

80

80

80

415

8.1

73.0

1.1

5.2

7.5

2.2

None

--

--

25.6

27.9

27.8

30.1

30

35

35

35

2TP04521850

13.5

18.8

49.1

51.4

51.3

53.6

50

60

60

60

2TP04522450

17.9

24.9

56.8

59.1

59.0

61.3

60

60

60

70

2TP04523650

25.4

35.3

69.8

72.1

72.0

74.3

70

80

80

80

2HP04535450

40.4

56.2

76.8

79.6

79.5

82.4

80

80

80

90

*.

Maximum HACR breaker of the same amp size is acceptable.

†.

Only 25.4 kW of electric heat can be simultaneously energized with the mechanical heating. The full 40.4 kW operates only if both compressors are locked out.