ACCESSORIES

Refer to Price Manual for specific model numbers.

Compressor Blanket - Designed to further reduce the nor-
mal operating sound and is required to meet Canadian sound
levels for units of three tons and below.

Refer to Price Manual for specific model numbers.

Blower Time Delay - Available to increase efficiency when
installed. Installs on indoor section and maintains blower for
approximately one minute after cooling thermostat has been
satisfied.

TXV KIT - 1TVM series TXV’s must be used to obtain system
performance. See Tabular Data Sheet for proper selection.

ROOM THERMOSTATS - A wide selection of compatible
thermosets are available to provide optimum performance
and features for any installation.

1H/1C, manual changeover electronic non-programmable
thermostat.

1H/1C, auto/manual changeover, electronic programmable,
deluxe 7-day, thermostat.

1H/1C, auto/manual changeover, electronic programmable.

* For the most current accessory information, refer to the
price book or consult factory.

SOUND POWER RATINGS*

* Rated in accordance with ARI 270-95 Standards.

TYPICAL INSTALLATION

TYPICAL FIELD WIRING

UNIT MODEL

(dBA)

024

75

030

76

036

76

042

76

048

76

060

76

MINIMUM 18” SERVICE ACCESS
CLEARANCE ON ONE SIDE

60” OVERHEAD
CLEARANCE

10” CLEARANCE
COIL AREA

WEATHERPROOF
DISCONNECT
SWITCH

THERMOSTAT

TO FURNACE OR
AIR HANDLER
TERMINAL BLOCK

NEC CLASS 1 WIRING

NEC CLASS 2 WIRING

TO INDOOR COIL

SEAL OPENING(S) WITH
PERMAGUM OR EQUIVALENT

CONTROL ACCESS PANEL

NOTE: ALL OUTDOOR WIRING

MUST BE WEATHERPROOF.

ALL FIELD WIRING TO BE IN ACCORDANCE WITH ELECTRIC CODE (NEC) AND/OR LOCAL CODES

POWER WIRING

208/230-1-60

CONTACTOR
TERMINALS

COIL

GND.

LUG

C

Y

R

G

W

Y

R

G

W

POWER WIRING
CONTROL WIRING
FACTORY WIRING

24 VOLT CONTROL WIRING
MINIMUM 18 GA. WIRE
(NEC CLASS 2)

FURNACE OR AIR HANDLER TERMINAL BLOCK

ROOM THERMOSTAT

CONDENSING UNIT

ALL OUTDOOR WIRING MUST BE WEATHERPROOF. USE COPPER CONDUCTORS ONLY.

TERMINAL W IS ONLY
REQUIRED ON SYSTEMS
WITH HEAT.

*

*