beautypg.com

York H*BE-F018 User Manual

Page 6

background image

332018-BTG-D-0208

6

Unitary Products Group

COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils

UNIT MODEL

FURNACE

COIL

MODEL

COOLING

CFM RANGE

(MIN.-MAX.)

W

RATED

CFM

NET MBH

SEER

1

EER

TOTAL

SENS.

HABE-F018S

450
750

14,17

FC/MC/PC/UC24

600

17.5

12.1

14.00

12.00

14,17

FC/MC/PC/UC30

600

17.5

12.1

14.00

12.00

14

HC30

600

17.3

12.1

14.00

12.00

HDBE-F024S

600

1000

14

FC/MC/PC32

800

23.0

16.6

14.00

12.00

17, 21

FC/MC/PC35

800

23.0

16.6

14.00

12.00

17

HC36

800

23.2

16.6

14.00

12.00

HD36

800

23.4

16.6

14.00

12.00

HCBE-F030S

800

1200

14,17,21

FC/MC/PC/UC36

1000

29.0

20.0

14.00

12.00

17

HC36

1000

29.6

20.5

14.00

12.00

HD36

1000

30.0

20.7

14.00

12.00

HABE-F036S

1000
1400

14

FC/MC/PC/UC37

1200

35.2

25.7

14.00

12.00

17,21

FC/MC/PC/UC42

1200

35.0

25.6

14.00

12.00

17,21

FC/MC/PC/UC43

1200

35.2

25.7

14.00

12.00

21,24

FC/MC/PC/UC48

1200

35.2

25.7

14.00

12.00

21

HC48

1200

34.6

25.3

14.00

12.00

HD48

1200

34.8

25.0

14.00

12.00

HBBE-F042S

1200
1600

21,24

FC/MC/PC/UC48

1400

39.5

28.9

13.50

11.00

21,24

FC/MC/PC/UC60

1400

40.5

29.6

14.00

12.00

21

HC42

1400

39.0

28.4

13.00

11.00

24

HC60

1400

40.0

29.6

14.00

12.00

HD48

1400

39.0

28.4

13.25

11.00

HD60

1400

40.0

28.4

14.00

12.00

HBBE-F048S

1400
1800

21,24

FC/MC/PC/UC48

1600

45.0

33.2

13.50

11.00

21,24

FC/MC/PC/UC60

1600

46.5

33.9

13.90

11.00

21

HC48

1600

45.0

32.6

13.30

11.00

24

HC60

1600

46.0

33.9

13.75

11.00

HD48

1600

45.0

32.4

13.50

11.00

HD60

1600

46.0

33.9

13.75

11.00

24

MC61

1600

47.0

34.3

14.00

12.00

HCBE-F060S

1600
2000

21,24

FC/MC/PC/UC60

1800

55.0

38.5

14.00

12.00

24

HC60

1800

55.0

38.5

14.00

12.00

HD60

1800

55.0

38.7

14.00

12.00

24

MC61

1800

55.5

38.9

14.00

12.00

24

FC/MC62

1800

55.5

38.9

14.00

12.00

1. Requires a 2FD06700224 Blower Time Delay unless a standard furnace is equipped with one.