• Be careful when handling the sharp edge of the mounting plate.

Wiring

• This indoor unit is ready for connection to the outdoor unit.

• Never modify the unit by removing any of the safety guards

or by passing any of the safety interlock swithces.

• Connect the interconnecting cable correctly and connect

the connecting cable to terminal as identified with their
respective marking.

• Do not damage the conductor core or inner insulation of

power supply cables and do not deform or crush the cables.

Piping

The auxiliary piping can be connected in the diections
shown the above diagram. To connect in the

D, E and

F direction, pipes will need to be extended.

• Bend pipes carefully to avoid flattening or obstructing

them if the pipes are bent incorrectly, the indoor unit
may be unstable on the wall.

• Carefully arrange pipes so that pipes do not stick out

of the rear plate of the indoor unit.

A

B

C

D

E

F

MODEL 24

Right

Right

Right

Right

Left

Rear Bottom

Drain hose

• Drain hose is flexible and can be routed to suit various

piping arrangements. The drain line must include elbow
trap (U bend). Connect a plastic condensate pipe with
an internal diameter of 12 mm.

• The drain hose can be connected to the left or the right side.

Verification of condensate water drainage:
Fill the drain pan with water and observe evacuation.

Note: Do not put the drain hose end into water.

Drain hose

For left and left rear piping

Drain cap

Drain cap

Drain hose

For right and right rear piping

CAUTION

CAUTIONS

CAUTIONS

Above 150mm from the ceiling