Wiring

Prepare the power source for exclusive with the air conditioner.
The supply voltage must comply with the rated voltage of the air conditioner: The plug socket shall be accessible after installation.
Remark: All the wiring must be based on the wiring nameplate which is shown on the model.

Perform the wiring with sufficient capacity. Installation places legally require a short circuit isolator to be attached to
prevent electrical shock.

Do not extend the power cable code by cutting.

Power voltage should be in the range of 90%~110% of rated voltage.

The plug of the air conditioner takes a grounding leg, and clients should use a grounding socket so that the air
conditioner can be grounded efficiently.

If the power cord is damaged, replacement should be conducted by qualified technician or a serviceman.

Note

Remark per EMC Directive 89/336/EEC

To prevent flicker impressions during the start of the compressor (technical process), following installation conditions do apply.
1. The power connection for the air conditioner has to be done at the main power distribution.

The distribution has to be of an low impedance, normally the required impedance reaches at a 32 A fusing point.

2. No other equipment has to be connected with this power line.
3. For detailed installation acceptance, please refer to your contract with the power supplier if restrictions do apply for

products like washing machines, air conditioner or electrical ovens.

4. For power details of the air conditioner, refer to the rating plate of the product.
5. For any question, contact your local dealer.

Cautions

Never modify the unit by removing any of the safety guards or by bypassing any of the safety interlock swithces.

Connect the connecting cable correctly and connect the connecting cable to terminal as identified with their respective marks.

Do not scratch the conductive core & inner insulator of power supply cables and do not deform or smash on the surface of cables.

Electrical Connections

All electrical wiring and connections must comply with local codes and standards. Power supply cord and interconnection
cord used must not be lighter than Polychloroprene sheeted cord (245 IEC 57 or H05RN-F).
Disconnecting device must have a contact separation of at least 3 mm.

Models : 07-18 (Cooling only)

Power supply

220-240V/1Ph/50Hz

220-230V/1Ph/60Hz

Indoor

L

N

1

2(N)

1

2(N)

Outdoor

NOTE

CAUTIONS

CAUTIONS

Models : 07-18 (Cooling and Heating)

Power supply

220-240V/1Ph/50Hz

220-230V/1Ph/60Hz

L

N

1

2(N) 3 4

1

2(N) 3 4

Outdoor

Indoor

Models : 24 (Cooling only / Cooling and Heating)

Outdoor

Indoor

For correct installation, a proper ground connection must be made for unit.

Power supply

220-240V/1Ph/50Hz

220-230V/1Ph/60Hz

L

N

1

2(N) S

1

2(N) S