beautypg.com

York H*RE024 User Manual

Page 5

background image

036-21315-001 Rev. A (0502)

Unitary Products Group

5

* Requires a 2FD Blower Time Delay unless a standard furnace is equipped with one.
**

Refer to Quick Selection Chart for specific furnace match-up.

H2RE060S06

1650
2150

21,24

G1FA060S21,24

1900

53.5

37.1

-

13.25

12.00

24

G2FD060S24

1900

53.5

37.1

-

13.25

12.00

24

G2FD061H24

2050

54.5

39.1

-

13.25

12.10

-

G1HD060

1900

52.5

36.0

-

13.00

11.75

24

G1NA060S24T

1900

53.0

35.9

-

13.00

11.90

21,24

G1UA060S21,24

1900

53.5

37.1

-

13.25

12.00

1.

TXV = Use 1TV700 Series Kit.

COOLING CAPACITY - Upflow, Downflow, & Horizontal Furnaces and Coils (Continued)

UNIT MODEL

FURNACE**

COIL

MODEL

COOLING

CFM RANGE

(MIN.-MAX.)

W

RATED

CFM

NET MBH

SEER + TXV

W/O TDR

SEER + TXV

1

+ TDR*

EER

TOTAL

SENS.

COOLING CAPACITY - With Variable Speed Furnaces

UNIT MODEL

VARIABLE SPEED

FURNACE MODEL

COIL MODEL

1

W

COOLING

RATED

CFM

NET MBH

SEER

W/O TXV

SEER

+ TXV

2

EER

TOTAL

SENS.

1 PH 14 SEER AC / P1DU / P1XD / P1XU - VARIABLE SPEED

3

H1RE024S06

P1DUA12V

G1FA036S14

14

870

25.4

18.0

-

15.00

13.60

P1DUA12V

G1UA036S14

14

870

25.4

18.0

-

15.00

13.60

P1DUA12V

G2FD035S14

14

870

25.2

17.9

-

15.00

13.50

P1XDB12V

G2FD030S17

17

830

26.0

17.9

-

15.00

13.65

P1XUB12V

G1FA036S17

17

870

25.4

18.0

-

15.50

13.75

P1XUB12V

G1UA036S17

17

870

25.4

18.0

-

15.50

13.75

P1XUB12V

G2FD030S17

17

870

25.4

17.9

-

15.50

13.75

P1XUB12V

G2FD036S17

17

870

25.8

18.1

-

15.50

13.90

H1RE030S06

P1DUA12V

G1FA036S14

14

1000

28.8

20.0

-

13.50

12.50

P1DUA12V

G1UA036S14

14

1000

28.8

20.0

-

13.50

12.50

P1DUB16V

G2FD036S17

17

1000

30.0

20.7

-

14.50

13.35

P1XDB12V

G2FD036S17

17

1040

30.2

20.7

-

14.00

12.50

P1XUB12V

G2FD036S17

17

1020

29.2

20.7

-

14.00

12.65

H1RE036S06

P1DUB16V

G2FD036S17

17

1200

34.4

24.5

-

14.00

12.70

P1DUC20V

G1FA048S21

21

1200

36.2

25.3

-

15.50

14.15

P1DUC20V

G1UA048S21

21

1200

36.2

25.3

-

15.50

14.15

P1DUC20V

G2FD036S21

21

1200

34.6

24.8

-

14.65

13.05

P1DUC20V

G2FD048S21

21

1200

36.0

25.7

-

15.50

13.95

P1XDB12V

G2FD036S17

17

1130

34.8

24.5

-

14.20

12.60

P1XDD20V

G2FD048S24

24

1195

36.2

25.7

-

14.50

13.10

P1XUB12V

G2FD036S17

17

1200

34.4

24.5

-

14.00

12.65

H2RE042S06

P1DUC20V

G1FA048S21

21

1400

39.5

28.4

-

14.50

12.45

P1DUC20V

G1FA060S21

21

1400

41.0

29.6

-

15.00

12.80

P1DUC20V

G1UA048S21

21

1400

39.5

28.4

-

14.50

12.45

P1DUC20V

G1UA060S21

21

1400

41.0

29.6

-

15.00

12.80

P1DUC20V

G2FD042S21

21

1400

39.5

28.2

-

14.00

12.30

P1DUC20V

G2FD048S21

21

1420

40.0

28.9

-

14.50

12.60

P1DUC20V

G2FD048S21

21

1420

40.0

28.9

-

14.50

12.50

P1XDD20V

G2FD048S24

24

1365

41.0

28.9

-

14.40

12.50

P1XDD20V

G2FD060S24

24

1420

41.5

33.8

-

14.40

12.55

H2RE048S06

P1DUC20V

G1FA060S21

21

1605

46.5

33.9

-

14.00

12.20

P1DUC20V

G1UA060S21

21

1605

46.5

33.9

-

14.00

12.20

P1DUC20V

G2FD048S21

21

1605

45.5

33.2

-

13.50

12.00

P1XDD20V

G2FD060S24

24

1580

47.0

33.9

-

13.80

12.20

H2RE060S06

P1XDD20V

G2FD060S24

24

1580

52.5

34.3

-

13.50

12.2

P1DUC20V

G1FA060S21

21

1630

53.0

34.9

-

13.60

12.4

P1DUC20V

G1UA060S21

21

1630

53.0

34.9

-

13.60

12.4

P1XUC20V

G1FA060S21

21

1590

53.0

34.5

-

13.50

12.4

P1XUC20V

G1UA060S21

21

1590

53.0

34.5

-

13.50

12.4

P1XUD20V

G1FA060S24

24

1560

53.0

34.4

-

13.75

12.5

P1XUD20V

G1UA060S24

24

1560

53.0

34.4

-

13.75

12.5

P1XUD20V

G2FD060S24

24

1560

53.0

34.4

-

13.75

12.5

P1XUD20V

G2FD061H24

24

1560

53.5

34.9

-

14.00

12.8

1. G2FD coils available with a factory installed horizontal drain pan. See price pages for specific model number.
2.

TXV = Use 1TV700 Series Kit.