COOLING CAPACITY - With Air Handler Coils

UNIT MODEL

AIR HANDLER

COIL

1

MODEL

COOLING

MODEL

ELECTRIC

2

HEAT KW

W

RATED

CFM

NET MBH

SEER

W/O TXV

SEER

+ TXV

3

EER

TOTAL SENS.

1 PH 14 SEER AC WITH N-AH / G2FD

H1RE024S06

N1AHB0806

2,5,8,10

17

G2FD036S17

800

25.2

18.1

-

14.00

12.35

H1RE030S06

N1AHB1206

5,8,10,15,19

17

G2FD036S17

1000

28.8

20.7

-

13.10

11.80

H1RE036S06

N1AHB1206

5,8,10,15,19

17

G2FD036S17

1200

34.0

24.5

-

13.35

11.80

N1AHB1206

5,8,10,15,19

17

G2FD046S17

1200

35.0

25.6

-

14.00

12.20

N1AHD1406

5,8,10,15

24

G2FD048S24

1200

35.4

25.7

-

14.00

12.50

N1AHD1406

5,8,10,15

24

G2FD060S24

1200

36.0

26.1

-

14.20

12.80

H2RE042S06

N1AHC1606

5,8,10,15,20

21

G2FD042S21

1400

39.0

28.2

-

13.25

11.35

N1AHC1606

5,8,10,15,20

21

G2FD048S21

1400

39.5

28.9

-

13.50

11.60

N1AHD1406

5,8,10,15

24

G2FD060S24

1400

40.5

29.6

-

14.00

12.00

H2RE048S06

N1AHD2006

8,10,15,20,25,30

24

G2FD060S24

1600

46.5

33.9

-

13.85

11.80

N1AHD2006

8,10,15,20,25,30

24

G2FD061H24

1600

47.0

34.3

-

14.00

11.90

H2RE060S06

N1AHD2006

8,10,15,20,25,30

24

G2FD060S24

1900

53.5

37.1

-

13.50

12.00

N1AHD2006

8,10,15,20,25,30

24

G2FD061H24

2050

54.5

39.1

-

13.50

12.10

1 PH 14 SEER AC / N1VS - VARIABLE SPEED

H1RE024S06

N1VSB12

10,15,18

17

G2FD036S17

870

25.6

18.1

-

15.00

13.85

N1VSB12

10,15,18

17

G2FD046S17

870

26.2

18.9

-

15.50

14.15

H1RE030S06

N1VSB12

10,15,18

17

G2FD036S17

1000

29.4

20.7

-

14.50

12.95

N1VSB12

10,15,18

17

G2FD046S17

1070

30.0

21.6

-

15.35

13.60

H1RE036S06

N1VSB12

10,15,18

17

G2FD046S17

1250

35.2

25.6

-

14.00

12.40

N1VSC16

10,15,18

21

G2FD048S21

1285

36.0

25.7

-

15.00

13.60

H2RE042S06

N1VSC16

10,15,18

21

G2FD048S21

1420

40.5

28.9

-

14.50

12.50

N1VSC16

10,15,18

21

G2FD048S21

1420

40.5

28.9

-

14.50

12.50

N1VSD20

10,15,18,30

24

G2FD060S24

1420

41.5

29.6

-

15.50

13.20

H2RE048S06

N1VSC16

10,15,18

21

G2FD048S21

1590

46.0

33.2

-

14.30

12.20

N1VSD20

10,15,18,30

24

G2FD060S24

1600

47.0

33.9

-

14.65

12.40

H2RE060S06

N1VSD20

8,10,15,20,25,30

24

G2FD060S24

1780

53.5

36.3

-

13.75

12.35

N1VSD20

8,10,15,20,25,30

24

G2FD061H24

1780

54.5

37.0

-

14.00

12.60

1 PH 14 SEER AC / F2RP / RC / FP / FC / FV

4,5

H1RE024S06

F2RP/FP036

5,8,10,15,19

21

-

800

25.0

18.0

-

13.80

12.30

F2FP040

5,8,10,15

21

-

800

25.4

17.4

-

14.00

12.75

H1RE030S06

F2RP/FP036

5,8,10,15,19

21

-

1000

29.8

21.5

-

13.85

12.40

F2FP045

5,8,10,15

24

-

1000

30.6

21.5

-

14.00

12.70

H1RE036S06

F2RP/FP036

5,8,10,15,19

21

-

1200

34.4

24.8

-

13.50

12.10

F2RP/FP042

5,8,10,15

21

-

1200

34.4

24.8

-

13.30

11.90

F2FP045

5,8,10,15

24

-

1200

36.0

25.5

-

14.00

12.65

H2RE042S06

F2FP045

5,8,10,15

24

-

1400

40.5

29.8

-

14.00

12.00

F2FP048

5,8,10,15,20,25

24

-

1400

39.5

28.9

-

13.25

11.30

H2RE048S06

F2FP060

5,8,10,15,20,25

24

-

1600

46.0

33.4

-

13.00

11.25

F2FV060

8,10,15,20,25

24

-

1625

47.5

34.9

-

15.50

13.20

H2RE060S06

F2FP060

10,15,20,25

24

--

1900

53.0

36.7

-

13.00

11.60

F2FV060

10,15,20,25

24

--

1900

53.5

36.3

-

13.75

12.35

Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210.
Cooling MBH based on 80°F entering air temperature, 50% RH, and rated air flow.

KW includes compressor, outdoor fan and indoor blower motor watts. Add-on coils include 365 watts/1000 CFM for blower motor.
EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at a 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power
input in watt-hours during the same period.

1. G2FD coils available with a factory installed horizontal drain pan. See price pages for specific model number.
2. Single phase units require single phase 2HK heaters.
3. TXV = Use 1TV700 Series Kit.
4. To meet R=4.2 insulation requirements, substitute F2FP for F2RP, and F2FC for F2RC

.

models. All ratings remain the same.

5. FG8, FG9, and FL8 furnaces and F2RP / F2RC air handlers have B.O.D (Blower on Delay) standard.