REMOVING THE BLOWER MOTOR CAPACITOR

WARNING

Personal Injury Hazard

Disconnect from the electrical supply be-
fore servicing the unit. Failure to do so
could result in death or electrical shock.

2.

Remove the microwave oven from its
mounting location (see page 2-2).

3.

Remove the vent grille and cabinet from
the microwave oven (see the illustration
on page 2-3).

4.

Remove the five screws from the air duct.

5.

Cut the wires near the body of the blower
motor capacitor.

6.

Remove

1

/

2

" of insulation from the cut wire

ends of the red harness wires and then
splice them to the wires of the new ca-
pacitor with two wire nuts.

7.

Install the new blower motor capacitor to
the air duct and reassemble the micro-
wave oven.

REMOVE FIVE

AIR DUCT SCREWS

1.

Disconnect the electrical supply to the
microwave oven.

AIR DUCT

WIRE NUT

MOUNTING SCREW

BLOWER MOTOR

CAPACITOR

CUT &

SPLICE