Cooktop Chimney Hood Installation

17

wolfappliance.com/specs

In-Line and Remote Blowers

IN-LINE OR REMOTE BLOWER WIRING

IMPORTANT NOTE:

Refer to installation instructions

provided with the in-line or remote blower assembly for

additional mounting and wiring instructions.

Blower connection at the hood:

1) Remove the cover from the front of the electrical box.

Remove the electrical box knockout that faces the

hood’s discharge collar.

2) Disconnect the red and black or white wires using a

flat-blade screwdriver.

3) Insert 6"

(152)

Romex

®

wire through the knockout

opening. Secure the Romex

®

wire to the electrical box

with an appropriate connector. Use wire connectors or

wire nuts approved by UL or C/UL.

4) Attach the remote blower wiring where wires were

removed in step 2. Attach white to white, black to red,

and ground to yellow.

5) Place all wiring connections inside the electrical box

and reinstall the cover. Make sure all wires are secure

and that no wires are pinched between the cover and

electrical box.

IMPORTANT NOTE:

Before turning the power on to the

ventilation hood, make sure the blower is off.