Cooktop Chimney Hood Installation

16

11

3

/

4

"

(298)

21

1

/

2

"

(546)

24

3

/

8

"

(619)

18

1

/

2

"

(470)

12

1

/

4

"

(311)

4

1

/

2

"

(114)

IN-LINE AND REMOTE BLOWER DIMENSIONS

600 CFM in-line blower.

18"

(457)

22"

(559)

24

7/8

"

(632)

12"

(305)

18"

(457)

8"

(203)

1100 CFM in-line blower.

600 CFM and 900 CFM remote blower.

1500 CFM remote blower.

1200 CFM remote blower.

24

1/2

"

(622)

15

1/2

"

(394)

28

1/4

"

(718)

20

3/4

"

(527)

24

3/4

"

(629)

14"

(356)

4

3/4

"

(121)

10"

(254)

DIAMETER

14

3/4

"

(375)

29

1/2

"

(749)

29

1/2

"

(749)

18"

(457)

22"

(559)

10

1/8

"

(257)

7

1/4

"

(184)

10"

(254)

10"

(254)

DIAMETER

14

3/4

"

(375)

29

1/2

"

(749)

29

1/2

"

(749)

21"

(533)

25"

(635)

10

3/8

"

(264)

7

1/4

"

(184)

10"

(254)

10"

(254)

DIAMETER

In-Line and Remote Blowers

BLOWER INSTALLATION

IMPORTANT NOTE:

Refer to specific installation instruc-

tions provided with each blower assembly for additional

mounting and wiring instructions.

Locate the blower so that the length of the duct run and

number of elbows and transitions are kept to a minimum.

The duct run should be no longer than 50'

(15 m)

. Remote

blowers should be located between wall studs or roof

rafters. Avoid pipes, wires and other ductwork.

Allow enough space for transitions needed between the

blower and connecting ductwork. For best performance,

locate transitions nearest the blower.

Refer to the illustrations below for overall dimensions of

Wolf in-line and remote blowers. Installation instructions

shipped with each Wolf ventilation product provide

detailed specifications. These instructions can also be

found on our website, wolfappliance.com/specs.