beautypg.com

Pre-installation, Aqua plus, Product manual – Weil-McLain AQUA PLUS GL-E223-ADOC 0311 User Manual

Page 5

background image

AQUA PLUS

indirect

-

fired

water

heaters

— Product Manual

Pre-installation

(continued)

Hot Water Can Scald!

• Water heated to temperature for clothes washing,

dish washing and other sanitizing needs can scald
and cause permanent injury.

• Children, elderly, and infirm or physically handi-

capped persons are more likely to be permanently
injured by hot water. Never leave them unattended
in bathtub or shower. Never allow small children to
use a hot water tap or draw their own bath.

• If anyone using hot water in the building fits

the above description, or if state laws or local
codes require certain water temperatures at
hot water taps, you must take special precau-
tions:

• Use lowest possible temperature setting.

• Install some type of tempering device, such

as an automatic mixing valve, at hot water
tap or water heater. Automatic mixing valve
must be selected and installed according
to valve manufacturer’s recommendations
and instructions.

• Water passing out of drain valves may be extremely

hot. To avoid injury:

• Make sure all connections are tight.

• Direct water flow away from any person.

Protection must be taken against excessive tem-
perature and pressure! — Installation of a tem-
perature & pressure (T&P) relief valve (provided
with water heater) and a thermostatic mixing valve
(provided by installer) is required.

Domestic water piping requirements

1. Install unions on all piping for easy removal of water heater.
2. Use

dielectric unions or couplings

to protect hot and cold water

fittings from corrosion when connecting dissimilar materials such

as copper and galvanized iron pipe.

3.

When the supply pressure is higher than 70 PSIG

, install a

pressure reducing valve on cold water supply line to prevent water

loss through T&P relief valve. A thermal expansion tank is also

required.

4. If the water heater will replace a tankless coil in the boiler, discon-

nect piping to coil or remove coil from boiler and replace with

a cover plate. Allow water to drain from coil.

Do not

plug the

tankless coil.

Plugging tankless coil inlet and outlet will result in severe

personal injury, death or substantial property damage.

Studies have indicated that dangerous bacteria,

including

legionella pneumophila

, can form in

the potable water distribution system if certain
minimum water temperatures are not maintained.
Contact your local health department for more
information.

Water heater operating restrictions

1. Read the operating limits under “Operating restrictions,” page 3.

Magnesium anode

— The water heater is equipped with

a magnesium sacrificial anode. The anode may erode over

time, and should be inspected at least once annually, only

by a qualified service technician. For installations with

a likelihood of poor water conditions, the anode should

be inspected at least every six months. Failure to comply

could result in loss of protection by the anode, causing

possible severe personal injury, death or substantial

property damage due to water heater leakage.

The domestic water chloride concentration must not ex-

ceed 200 ppm. High chloride concentrations can rapidly

disintegrate the water heater’s protective anode.

Boiler water restrictions

1. Read the WARNINGS under “Boiler water restrictions,” page 3.

Part number GL-E223-ADOC 0311