Boiler-side wiring and controls

Electrical shock hazard

— Can cause severe personal

injury, death or substantial property damage. Disconnect

power before installing and / or servicing.

Wiring requirements

1. All wiring must be a minimum of 18 gauge and installed in accordance

with:
• U.S.A. — National Electrical Code and any other national, state or

local code requirements having jurisdiction.

• Canada — CSA C22.1 Canadian Electrical Code Part 1 and any

other national, provincial and local code requirements having

jurisdiction.

2. If original wire as supplied with appliance must be replaced, Type 90°

C or its equivalent must be used.

3. Refer to control component instructions packed with boiler for ap-

plication information.

4. An optional service switch may be installed in water heater electri-

cal circuit. This switch would only shut off the water heater, not the

home heating system. Do not shut off water heater if there is a chance

of freezing.

5. All electrical contacts are shown with no power applied — off-the-

shelf condition.

Circulators

1. Size priority relay for total amp draw of all circulators.

Zone Valves

1. Size transformer for maximum load of all zone valves.

Wiring to the water heater

1. Field connections to the water heater thermostat are for 24 VAC only,

connecting to the two-pole terminal block shown in Figure 17.

Wiring options

1. This manual shows wiring only for use of Weil-McLain WMCR Cir-

culator Zone Controller or Weil-McLain WMZV Zone Valve Zone

Controller.

2. Other wiring methods may be acceptable and are left to the installer.

Use domestic priority

1. When possible, set controls to provide domestic

priority — that is, on a call for domestic water

the control switches from space heating to DHW

only.

2. Domestic priority ensures the fastest possible re-

sponse to the DHW call for heat.

3. The smaller the water heater, the greater the need

for rapid response.

Figure 17

Inspection hatch assembly (hatch

cover shown transparent)

1

Temperature adjustment knob

2

Inspection plate (handhole)

3

Factory wires from thermostat to field wiring terminal

block

4

Field wiring terminal block

5

M8 hex nut

6

Inspection plate bracket

Part number GL-E223-ADOC 0311