1. Lock the gun and turn the pump OFF

(O).

3. When suction set is clean, thread the suction tube back

into the inlet valve, and replace the return tube onto the
return tube fitting. Replace clip.

4. Submerge the suction set into a bucket of

NEW cleaning

solution.

5. Turn the PRIME/SPRAY knob to PRIME. Turn the pump

ON

(l), and trigger the gun once into a waste container to

relieve pressure.

(a)

2. Remove the suction hose and return tube and clean it

using the appropriate cleaning solution. You should also
wipe the threads of the inlet nut

(a) and remove and clean

the inlet filter of the suction tube.

GX-08

GX-07

GX-05

O

2 to 3

minutes

6. Let the pump circlulate cleaning solution through the suction

set for 2-3 minutes. Turn the pump OFF.

IMPORTANT!

If you used oil-based materials, you must flush the pump
again using water to prepare it for storage. Repeat #1 - #11
in Cleanup- Latex materials, instructions.

Move on to Cleaning the Spray Gun Components.