Pre l iminar y – Vidikron 85 User Manual
Page 18
6
Vidikron Vision 85 Owner’s Operating Manual
PRE
L
IMINAR
Y
1.
VERTICAL LENS SHIFT
Using a 9/64” hex wrench, turn this to move the lens up or down.
2.
POWER LED
Lights red to indicate that the projector is in standby; flashes blue during warm-up or
cool-down or lights blue to indicate normal operation.
3.
LAMP LED
Lights blue to indicate normal lamp operation; lights red if the lamp has failed.
4.
TEMP LED
Lights red to indicate that the projector has overheated and shut down.
5.
EXHAUST VENTS
Hot air exits the projector through these vents. This air can be quite hot. Ensure that
there are no heat-sensitive objects near it and that it is never blocked.
6.
CABLE OPENING
Pass cables through this opening.
7.
INTAKE VENTS
Cool air enters the projector through these vents. To prevent overheating, ensure that
these vents are never blocked.
8.
ZOOM TAB
Turn this tab to make the projected image larger or smaller.
9.
VIDIKRON LOGO
You can rotate the logo to match the projector orientation: inverted (ceiling-mounted)
or upright. To rotate the logo, grip it at the sides, pull it away from the projector and
rotate it 180 degrees.
10. FOCUS RING
Turn this ring to focus the image.
11. LAMP COVER
Remove this cover to access the lamp compartment.
12. REAR PANEL ACCESS DOOR
To access the connector panel,
press the door release button so it
pops out. Turn the knob clockwise
or counter-clockwise and pull
gently on it to open the door.