Toshiba RAS-13UAV-E2 User Manual
Page 82
FILE NO. SVM-03008
– 81 –
1) Cut the sensor 100 mm longer than old one.
2) Cut the protective tube after pulling out it
(200 mm).
3) Move the protective tube toward the thermal
sensor side and tear the tip of lead wire in two,
then strip the covering part.
4) Pass the stripped part through the thermal
constringent tube.
5) Cut the old sensor 100 mm length on the
connector side, and recycle that connector.
6) Tear the lead wire in two on the connector side
and strip and covering part.
7) Twist the leads on the connector and sensor
sides, and solder them.
8) Move the thermal constringent tubes toward
the soldered parts and heat them with the
dryer and constring them.
9) Wind the attached color tape round the both
terminals of the protective tube when colored
protective tube is used.
10) Fix the sensor again.
NOTES:
1) Store the joint part of the sensor and the
connector in the electric parts box.
2) Never joint them near the thermal sensor part.
Otherwise, it would cause insulation inferiority
because of dew drops.
3) When replacing the sensor using the colored
protective tube, wind the color tape matching
the color of that tube.
"
Replacement of
temperature
sensor for
servicing only
Common service
parts of sensor
TO, TS, TE, TD
These are parts for
servicing sensors.
Please check that
the accessories
shown in the right
table are packed.
Part name
Q’ty
Remarks
1
Sensor
1
Length: 3 m
2
Sensor Spring (A)
1
For spare
3
Sensor Spring (B)
1
For spare
4
Thermal constringent tube
3
Including one spare
5
Color tape
1
9 colors
6
Terminal
3
No.
Part name
Procedures
Remarks
Cutting here
Cutting here
Thermal
constringent tube
Soldered part
Dryer
Winding the color tape
200
100
15
70
Thermal
sensor part
Connector
Cutting here
100
15
70