beautypg.com

Toshiba RAS-13UAV-E2 User Manual

Page 82

background image

FILE NO. SVM-03008

– 81 –

1) Cut the sensor 100 mm longer than old one.
2) Cut the protective tube after pulling out it

(200 mm).

3) Move the protective tube toward the thermal

sensor side and tear the tip of lead wire in two,
then strip the covering part.

4) Pass the stripped part through the thermal

constringent tube.

5) Cut the old sensor 100 mm length on the

connector side, and recycle that connector.

6) Tear the lead wire in two on the connector side

and strip and covering part.

7) Twist the leads on the connector and sensor

sides, and solder them.

8) Move the thermal constringent tubes toward

the soldered parts and heat them with the
dryer and constring them.

9) Wind the attached color tape round the both

terminals of the protective tube when colored
protective tube is used.

10) Fix the sensor again.

NOTES:
1) Store the joint part of the sensor and the

connector in the electric parts box.

2) Never joint them near the thermal sensor part.

Otherwise, it would cause insulation inferiority
because of dew drops.

3) When replacing the sensor using the colored

protective tube, wind the color tape matching
the color of that tube.

"

Replacement of
temperature
sensor for
servicing only

Common service
parts of sensor
TO, TS, TE, TD

These are parts for
servicing sensors.

Please check that
the accessories
shown in the right
table are packed.

Part name

Q’ty

Remarks

1

Sensor

1

Length: 3 m

2

Sensor Spring (A)

1

For spare

3

Sensor Spring (B)

1

For spare

4

Thermal constringent tube

3

Including one spare

5

Color tape

1

9 colors

6

Terminal

3

No.

Part name

Procedures

Remarks

Cutting here

Cutting here

Thermal
constringent tube

Soldered part

Dryer

Winding the color tape

200

100

15

70

Thermal
sensor part

Connector

Cutting here

100

15

70