beautypg.com

Toshiba RAS-13UAV-E2 User Manual

Page 61

background image

– 60 –

FILE NO. SVM-03008

(3) Only indoor fan motor does not operate.


(1) Is it possible to detect the power supply voltage (200 – 240 V) between

1

and

2

on the terminal block?

(2) Does the indoor fan motor operate in cooling operation?

(In heating operation, the indoor fan motor does not operate for approximately 5 minutes after it is turned on,
to prevent a cold air from blowing in.)

Turn off power

supply once, and

turn it on again.

Start to operate

indoor unit in cooling

operation at airflow

level LOW .

Turn off indoor unit and

remove connector from motor.

Then start to operate indoor

unit with remote control.

Turn off indoor unit and remove

connector from motor.

Then push START/STOP button

on remote control to stop

flashing lamp on indoor unit.

Change airflow level

to HIGH .

Turn off indoor unit

and rotate cross-flow

fan by hand when the

unit is on standby.

At this time, is it possible

to detect DC 1V or more

between

5e

and

3d

of motor connector

(CN10).

Start to operate the

indoor unit in except

heating operation.

At this time, is it possible

to detect DC 1V or more

between

5e

and

3d

of motor connector (CN10)?

(Check this condition

within 15 seconds after

starting unit.)

Start to operate the

indoor unit in except

heating operation.

At this time, is it possible to

detect DC 1V or more between

5e

and

3d

of motor

connector (CN10)?

Is it possible to detect

DC 1V or more between

5e

and

3d

of

motor connector (CN10).

Is it possible to detect

DC 310

340 V between

1e

and

3d

of motor

connector (CN10).

(Motor connection condition)

Is it possible to detect DC 15 V

between

4e

and

3d

of

motor connector (CN10).

Is it possible to detect

DC 15 V between

4e

and

3d

of motor

connector (CN10).

Is it possible to

change airflow level

to HIGH ?

Is it possible to

rotate cross-flow fan by

hand properly?

Does fan motor

continue to operate?

Does indoor

fan operate?

Fan motor

operates normally.

Peplace indoor

fan motor.

Peplace main

P.C. board.

Peplace

bearing.

YES

YES

YES

YES

YES

YES

YES

YES

YES

YES

NO

NO

YES

NO

NO

NO

NO

NO

NO

NO

NO

NO

This manual is related to the following products: