beautypg.com

Toshiba RAS-13UAV-E2 User Manual

Page 79

background image

FILE NO. SVM-03008

– 78 –

1) Disconnect lead wires and connectors

connected from the control board
assembly to other parts.
1. Lead wires

Connection with terminal block :
3 wires (Black, White, Orange)

Connection with compressor :
Remove the connector (3P)

Connection with reactor :
Remove the relay connectors from P07, 08
(2P, White) and P12, 13 (2P, Yellow).

2. Connectors

CN300 : Outdoor fan (3P, White)
CN301 : Outdoor fan position detection

(5P, White)

CN701 : 4-way valve (3P, Yellow)
CN600 : TE sensor (2P, White)
CN601 : TD sensor (3P, White)
CN603 : TS sensor (3P, White)
CN602 : TO sensor (2P, White)
CN500 : Case thermo. (2P, White)
CN703 : Pulse modulating valve

(6P, White)

2) Remove the control board assembly from

P.C. board base.
1. Main control board assembly side

Remove two claws of P.C. board base, and
remove upward the heat sink with hands.

Remove three screws fixing the heat sink
and main control board assembly side, and
replace the board with a new one.

1) Perform work of item 1 of 1,

1

and

2

,

3

.

2) Remove fixed screws fixing to the bottom plate.

(ST1T

4 x 10

s

3 pcs.)

3) Remove fixed screws fixing to the heat

exchanger. (ST1T

4 x 10

s

2 pcs.)

4) Remove fixed screw fixing to the valve mounting

plate. (ST1T

4 x 10

s

1 pc.)

4

Control board
assembly

5

Rear cabinet

CN300, CN301 and CN701, etc. at the
control board assembly side are
connectors with locks. Therefore,
remove the connector while pushing
the part indicated by an arrow.

No.

Part name

Procedures

Remarks

CN701

CN500

CN703

CN602

CN301

CN300

CN603

CN601

CN600

P.C. board base

P.C. board

When mounting a new board, check
that the board is correctly set in the
groove of base holder of P.C. board
base.

Reactor