9-2-4. Wiring connection
Wiring of the connecting cable can be carried out
without removing of the front panel.
1. Remove the air inlet grille.
Open the air inlet grille upward and pull it toward
you.
2. Remove the terminal cover and cord clamp.
3. Insert the connecting cable (according to the local
cords) into the pipe hole on the wall.
4. Take out the connecting cable through the cable
slot on the rear panel so that it protrudes about
15 cm from the front.
5. Insert the connecting cable fully into the terminal
block and secure it tightly with screws.
6. Tightening torque : 1.2 N·m (0.12 kgf·m)
7. Secure the connecting cable with the cord clamp.
8. Fix the terminal cover, rear plate bushing and air
inlet grille on the indoor unit.
CAUTION
•
Be sure to refer to the wiring system diagram
labeled inside the front panel.
•
Check local electrical cords and also any specific
wiring instructions or limitations.
Fig. 9-2-6
NOTE:
•
Wire type : More than H07RN-F or 245 IEC66
(1.0 mm
2
or more)
Fig. 9-2-7 Stripping length of connecting cable
Terminal cover
Screw
Cord clamp
Connecting cable
Screw
Screw
Terminal block
Earth line
Connecting
cable
Earth line
10 mm
10 mm
10 mm
50 mm
80 mm
9-2-5. Piping and drain hose installation
*
Since dewing results in a machine trouble, make
sure to insulate both the connecting pipes. (Use
polyethylene foam as insulating material.)
Fig. 9-2-8
1. Die-cutting Front panel slit
Cut out the slit on the left or right side of the front panel
for the left or right connection and the slit on the
bottom left or right side of the front panel for the
bottom left or right connection with a pair of nippers.
2. Changing drain hose
For left connection, bottom-leftward connection and
rear-leftward connection’s piping, it is necessary to
change the drain hose and drain cap.
Fig. 9-2-9
a heat insulator.
Fig. 9-2-10
Rear right
Rear left
Die-cutting
F
ront panel slit
Changing
dr
ain hose
Piping prepar
ation
Bottom left
Left
Bottom right
Right
Heat insulator
Drain hose
About 15 cm