beautypg.com

Caution – Toshiba RAS-13UAV-E2 User Manual

Page 46

background image

– 45 –

FILE NO. SVM-03008

9-2-4. Wiring connection

Wiring of the connecting cable can be carried out
without removing of the front panel.

1. Remove the air inlet grille.

Open the air inlet grille upward and pull it toward
you.

2. Remove the terminal cover and cord clamp.
3. Insert the connecting cable (according to the local

cords) into the pipe hole on the wall.

4. Take out the connecting cable through the cable

slot on the rear panel so that it protrudes about
15 cm from the front.

5. Insert the connecting cable fully into the terminal

block and secure it tightly with screws.

6. Tightening torque : 1.2 N·m (0.12 kgf·m)
7. Secure the connecting cable with the cord clamp.
8. Fix the terminal cover, rear plate bushing and air

inlet grille on the indoor unit.

CAUTION

Be sure to refer to the wiring system diagram
labeled inside the front panel.

Check local electrical cords and also any specific
wiring instructions or limitations.

Fig. 9-2-6

NOTE:

Wire type : More than H07RN-F or 245 IEC66

(1.0 mm

2

or more)

Fig. 9-2-7 Stripping length of connecting cable

Terminal cover

Screw

Cord clamp

Connecting cable

Screw

Screw

Terminal block

Earth line

Connecting
cable

Earth line

10 mm

10 mm

10 mm

50 mm

80 mm

9-2-5. Piping and drain hose installation

*

Since dewing results in a machine trouble, make
sure to insulate both the connecting pipes. (Use
polyethylene foam as insulating material.)

Fig. 9-2-8

1. Die-cutting Front panel slit
Cut out the slit on the left or right side of the front panel
for the left or right connection and the slit on the
bottom left or right side of the front panel for the
bottom left or right connection with a pair of nippers.

2. Changing drain hose
For left connection, bottom-leftward connection and
rear-leftward connection’s piping, it is necessary to
change the drain hose and drain cap.


Clip drain cap by needle-nose pliers, and pull out.

Fig. 9-2-9


Firmly insert drain hose connecting part until hitting on
a heat insulator.

Fig. 9-2-10

Rear right

Rear left

Die-cutting

F

ront panel slit

Changing

dr

ain hose

Piping prepar

ation

Bottom left

Left

Bottom right

Right

Heat insulator

Drain hose

About 15 cm

This manual is related to the following products: