beautypg.com

TechniSat MultyFocus User Manual

Page 41

background image

41

No picture, no sound, display is off

No picture, no sound, display is on

Screen display „Pulse count error“

Screen display „Motor overload“

Screen display „Auto-focus error“

Outdoor unit moves in wrong direction

The automatic satellite scan feature does not find any
satellites

The automatic satellite scan feature does not find a
number of satellites

Outdoor unit moves but does not find any satellite positions

check mains cable and connector

check all cable connections (see 4 „Connections“)

set channel 39 on the television set (see operating
instructions of the TV set)

select the right outdoor unit

check all cable connections (see 4 „Connections“)

move dish in reverse direction

Use an appropriate motor

not necessary

change motor connections M1 and M2

first of all, select the westernmost satellite (see 5.4)

select manually (see 5.4)
select manually (see 5.4)

consult a specialist to have the trajectory adjusted correctly

mount the polarizer according to the instructions

No supply voltage

cable connection is broken or missing

television set is set to the wrong channel

wrong outdoor unit selected

cable connection is broken or missing

you have reached the East or West limit

The power requirements of the connected motor are
too high

Due to a weak receive signal, auto-focus could not
detect optimal positioning; receiver uses the stored
position

motor connections M1 and M2 exchanged

automatic scan only works from West to East

Low receive quality
Other satellites are using the same broadcasting
frequencies

wrong outdoor unit selected
outdoor unit trajectory adjusted incorrectly
polarizer mounted incorrectly

9 Troubleshooting notes

Error

Possible cause

Measures

*M-Focus 2.6.95 14.12.1999 10:39 Uhr Seite 41