Issuing labels with net weight statement, 5 issuing labels with net weight statement – Toshiba TEC H-9000 User Manual
Page 71
12. OPERATING PROCEDURES
12.5 ISSUING LABELS WITH NET WEIGHT STATEMENT
12- 9
12.5 ISSUING LABELS WITH NET WEIGHT STATEMENT
NOTE: This operation is available only when the optional scale unit is connected.
Menu: REG., M.DOWN, or REWRAP
Mode: FIX
When the initial settings #1-7 and #1-8 are set to 1, a Net Weight Statement is printed on the label.
A unit price and a tare registered in each PLU are printed as a price and a net weight.
Example) The preset Price is $2.10 and the preset Net Weight is 12 oz. The store knows that the
actual Net Weight of this commodity is 19 oz. and decides to sell it at $2.00.
Enter the PLU #.
Press
Enter the new weight.
(unit of weight: oz)
displayed in the incremental
display method, i.e., the data
is shifted to the left as each
digit value is entered.)
Enter the new price.
Press:
8
1
6
PLU
2
0
Initial set #7-1: 0
The label is issued.
AUTO
Press:
MANUAL
The label is issued. (Labels of identical print
data will automatically be issued consecutively by
peeling the label off the backing paper.)
Initial set #7-1:1
Initial set #1-7:1
Press:
Enter the quantity.
1
9
C
PLU
Press, to cancel label
issue temporarily.
Press, to cancel
label issue.
Press, to return the PLU data to
the PLU file.
PRT
*
PRT
*
Initial set #1-7:0
3
FOR
C
0