9.

PROGRAMMING PROCEDURES

9.14 IN-LINE/LOCAL

9- 23

9.14

IN-LINE/LOCAL

Menu Page: 2
Item No.:

3

When the H-9000 is used as a satellite in an in-line system, the “ID #” and “Transmission delay time”
can be set by the following procedure.

NOTES: 1. The TMCC baud rate is fixed to 4800 BPS.

2. After setting the ID #, turn the power switch OFF and ON again.
3. This setting is not available in case that the Initial set #13-6 is set to 1 (LAN: allowed).

g Table 5: Transmission Delay Time Table

TR-Time (ms)

TR-Time (ms)

1

20 - 39

6

120 - 139

2

40 - 59

7

140 - 159

3

60 - 79

8

160 - 179

4

80 - 99

9

180 - 199

5

100 - 119

3

Page 2

PROG.

ESC.

Page 2

Main

ENTER

The transmission
delay time can be
set when in-line
system is selected
for TMCC.
(Refer to Table 5)

Select mode

TMCC

Set ID numbers

(Range: 0-255)

ENTER

OFF-line

l

The default is 3.