beautypg.com

How to diagnose the trouble – Toshiba CARRIER RAS-15LKV-UL User Manual

Page 66

background image

– 6

6

11. HOW TO DIAGNOSE THE TROUBLE

The pulse motor circuits are mounted to both indoor and outdoor units.

Therefore, diagnose troubles according to the trouble diagnosis procedure as described below.
(Refer to the check points in servicing written on the wiring diagrams attached to the indoor/outdoor units.)

Table 11-1

‹

‹

‹

‹

‹ Precautions when handling the new inverter (3DV Inverter)

CAUTION: HIGH VOLTAGEN

The high voltage circuit is incorporated.

Be careful to do the check service, as the electric shock may be caused in case of touching parts on the
P.C. board by hand.

The new inverter (3DV inverter) will be incorporated starting with this unit.

(3DV: 3-shunt Discrete Vector control)

‹

‹

‹

‹

‹ The control circuitry has an uninsulated construction.

Fig. 11-1

IGBT × 6

FET × 6

MCU

Compressor

Fan motor

Shared potential

Driver

Driver

Amplifier

Amplifier

No.

1

2

3

4

5

6

7

8

9

10

Troubleshooting Procedure

First Confirmation

Primary Judgment

Judgment by Flashing LED of Indoor Unit

Self-Diagnosis by Remote Controller (Check Code)

Judgment of Trouble by Every Symptom

Check Code 18 and 1E

Troubleshooting

How to Diagnose Trouble in Outdoor Unit

How to Check Simply the Main Parts

How to Simply Judge Whether Outdoor Fan Motor is Good or Bad

FILE NO. SVM-10020