Specifications of electrical parts, 1. indoor unit, 2. outdoor unit – Toshiba CARRIER RAS-15LKV-UL User Manual
Page 20
6. SPECIFICATIONS OF ELECTRICAL PARTS
6-1. Indoor Unit
11 Pressure SW.
ACB-4UB82W
4.7 MPa
15LKV-UL, 17LKV-UL
(for indoor)
22LKV-UL
2 Room temp. sensor (TA-sensor)
10k
Ω
at 25°C
3
Heat exchanger temp. sensor (TC-sensor)
10k
Ω at 25°C
4 Louver motor
Output (Rated) 1W, 16 poles, DC12V
(
− )
(
−
)
MP24Z3T
ICF-340U30-2 DC340V, 30W
1
No.
Fan motor
Parts name
Specifications
Type
FILE NO. SVM-10020
6-2. Outdoor Unit
No.
1
2
3
4
5
6
7
8
9
10
Parts name
Reactor
Outdoor fan motor
Suction temp. sensor (TS sensor)
Discharge temp. sensor (TD sensor)
Outside air temp. sensor (TO sensor)
Heat exchanger temp. sensor (TE sensor)
Terminal block (5P)
Compressor
15LAV-UL, 17LAV-UL
22LAV-UL
Coil for PMV
Coil for 4-way valve
Model name
CH-57
ICF-340UA40-2
(Inverter attached)
(Inverter attached)
(Inverter attached)
(Inverter attached)
——
DA130A1F-27F
1
DA150A1F-20F
1
CAM-MD12TCTH-4
STF
Rating
L = 10mH, 16A
DC340V, 40W
10k
Ω (25°C)
62k
Ω (20°C)
10k
Ω (25°C)
10k
Ω (25°C)
20A, AC250V
3-phases 4-poles 1100W
DC12V
– 20 –