beautypg.com

Specifications of electrical parts, 1. indoor unit, 2. outdoor unit – Toshiba CARRIER RAS-15LKV-UL User Manual

Page 20

background image

6. SPECIFICATIONS OF ELECTRICAL PARTS

6-1. Indoor Unit

11 Pressure SW.

ACB-4UB82W

4.7 MPa

15LKV-UL, 17LKV-UL

(for indoor)

22LKV-UL

2 Room temp. sensor (TA-sensor)

10k

at 25°C

3

Heat exchanger temp. sensor (TC-sensor)

10k

Ω at 25°C

4 Louver motor

Output (Rated) 1W, 16 poles, DC12V

(

− )

(

)

MP24Z3T

ICF-340U30-2 DC340V, 30W

1

No.

Fan motor

Parts name

Specifications

Type

FILE NO. SVM-10020

6-2. Outdoor Unit

No.

1

2

3

4

5

6

7

8

9

10

Parts name

Reactor

Outdoor fan motor

Suction temp. sensor (TS sensor)

Discharge temp. sensor (TD sensor)

Outside air temp. sensor (TO sensor)

Heat exchanger temp. sensor (TE sensor)

Terminal block (5P)

Compressor

15LAV-UL, 17LAV-UL

22LAV-UL

Coil for PMV

Coil for 4-way valve

Model name

CH-57

ICF-340UA40-2

(Inverter attached)

(Inverter attached)

(Inverter attached)

(Inverter attached)

——

DA130A1F-27F

1

DA150A1F-20F

1

CAM-MD12TCTH-4

STF

Rating

L = 10mH, 16A

DC340V, 40W

10k

Ω (25°C)

62k

Ω (20°C)

10k

Ω (25°C)

10k

Ω (25°C)

20A, AC250V

3-phases 4-poles 1100W

DC12V

– 20 –