Caution, 4. outdoor unit – Toshiba CARRIER RAS-15LKV-UL User Manual

Page 60

background image

CAUTION

Install the drain pipe for proper drainage.

Improper drainage can result in water dripping
inside the room.

This air conditioner has been designed to drain
water collected from condensation which forms on
the back of the indoor unit, to the drain pan.

Therefore, do not locate the power cord and other
parts at a heigh place than the drain guide.

Space for
pipes

Wall

Drain
guide

Fig.

10-3-21

10-4. Outdoor Unit

10-4-1. Installation Location

• A location which provides enough space around the

outdoor unit as shown in the diagram.

• A location which can bear the weight of the outdoor

unit and does not allow an increase in noise level
and vibration.

• A location where the operation noise and discharged

air do not disturb neighbors.

• A location which is not exposed to a strong wind.

• A location free of combustible gases.

• A location which does not block a passage.

• A location where the drain water does not cause any

problems.

• Depending on snow level, use a field fabricated ice

or snow stand.

• When the outdoor unit is to be installed in an elevated

position, be sure to secure its feet.

Precautions for adding refrigerant

• Use a scale having a precision with at least 10 g

per index line when adding the refrigerant.

Do not use a bathroom scale or similar instrument.

• Use liquid refrigerant when refilling the refrigerant.

Since the refrigerant is in liquid form, it can fill
quickly.

Therefore, perform the filling operation carefully
and insert the refrigerant gradually.

CAUTION

1. Install the outdoor unit without anything

blocking the discharging air.

2. When the outdoor unit is installed in a place

always exposed to strong winds like on the
coast or on a high story of a building, secure
the normal fan operation using a duct or a
wind shield.

3. Especially in windy areas, install the unit to

prevent the admission of wind.

4. Installation in the following places may result

in trouble.

Do not install the unit in such places.

• A place full of machine oil.

• A saline-place such as the coast.

• A place full of sulfide gas.

• A place where high-frequency waves are

likely to be generated, such as from audio
equipment, welders, and medical equip-
ment.

Fig. 10-4-1

Strong
wind

10-4-2. Refrigerant Piping Connection

Flaring

1. Make sure you have enough pipe to reach indoor unit.

90

°

Obliquity

Roughness

Warp

Warp

2. Cut the pipe with a pipe cutter.

Fig. 10-4-2

Fig. 10-4-3

3. Insert a flare nut into the pipe and flare the pipe.

FILE NO. SVM-10020