Item

2. Indoor fan

motor control

Operation flow and applicable data, etc.

(This operation controls the fan speed at indoor unit side.)

The indoor fan (cross flow fan) is operated by the phase-
control induction motor. The fan rotates in 5 stages in
MANUAL mode, and in 5 stages in AUTO mode, respec-
tively. (Table 1)

Description

* Symbols

UH

: Ultra High

H

: High

M+

: Medium+

M

: Medium

L+

: Low+

L

: Low

L-

: Low–

UL

: Ultra Low

SUL

: Super Ultra Low

* The values of fan speed and air flow

volume indicate on the table are measured

when the louver is inclined downward.
Fan speed and air flow volume broadly

vary with position of louver.

1) When setting the fan speed to L,

L+, M, M+ or H on the remote
controller, the operation is
performed with the constant
speed shown in Fig. 1.

2) When setting the fan speed to

AUTO on the remote controller,
revolution of the fan motor is
controlled to the fan speed level
shown in Fig. 2 and Table 1
according to the setup temperature
and room temperature.

(Fig. 1)

(Fig. 2)

(Table 1) Indoor fan air flow rate

+4.5 (+2.5)

Ta

°F [°C]

+3.5 (+2.0)

+2.7 (+1.5)

+2.0(+1.0)

+1.0 (+0.5)

Tsc

a

b

c

d

e

M+(WB)

*3

*4

*5

L(W6)

Air volume AUTO

L

L+

M

M+

H

W6

(L + M) / 2

W9

(M + H) / 2

WC

Indication

Fan speed

Fan speed setup

COOL ON

AUTO

MANUAL

*3 : Fan speed = [(M+) –L] x 3/4 + L

*4 : Fan speed = [(M+) –L] x 2/4 + L

*5 : Fan speed = [(M+) –L] x 1/4 + L

(Linear approximation
from M+ and L)

FILE NO. SVM-10020

Fan speed

Air flow rate

Fan speed

Air flow rate

(rpm)

cfm (m3/h)

(rpm)

cfm (m3/h)

WF

UH

1100

583 (991)

1200

648 (1101)

WE

H

1100

583 (991)

1200

648 (1101)

WD

UH M+ UH

1090

577 (980)

1200

648 (1101)

WC

H

H

1070

563 (957)

1180

635 (1079)

WB M+

M+ 980 505 (858) 1080 570 (968)

WA

M

940 479 (813) 1020 531 (902)

W9

M

L+

890

446 (758)

980

505 (858)

W8

L

780

374 (636)

850

420 (713)

W7

L+

L-

L+

750

355 (603)

810

394 (669)

W6

L

L

740

348 (591)

800

387 (658)

W5

L-

UL

L-

700

322 (547)

760

361 (614)

W4

UL

UL

700

322 (547)

700

322 (547)

W3

SUL

SUL

650

290 (492)

650

290 (492)

W2

SUL

500

191 (325)

500

191 (325)

W1

500

191 (325)

500

191 (325)

RAS-17LKV-UL, RAS-22LKV-UL

Fan speed

level

DRY

HEAT

COOL

RAS-15LKV-UL