3 parameter measurement information – Texas Instruments TCM4300 User Manual
Page 24
3–1
3 Parameter Measurement Information
This section contains the timing waveforms and parameter values for MCLKOUT and several
microcontroller interface configurations possible when using the TCM4300. The timing parameters are
contained in Section 3.1 through Section 3.11. The timing waveforms are shown in Figures 3–1 through
3–11. All parameters shown in the separate waveforms have their values listed in an associated table. Not
all parameter values listed in the tables are necessarily shown in an associated waveform.
3.1
MCLKOUT Timing Requirements (see Figure 3–1 and Note 1)
MIN
NOM
MAX
UNIT
twH
Pulse duration , MCLKOUT high
9
10
12
ns
twL
Pulse duration, MCLKOUT low
9
10
12
ns
tr
Rise time, MCLKOUT
2
3
4
ns
tf
Fall time, MCLKOUT
2
3
4
ns
NOTE 1: Tested with 15 pF loading on MCLKOUT
twH
tr
tf
twL
VOH
VOL
MCLKOUT
Figure 3–1. MCLKOUT Timing Diagram