beautypg.com

Texas Instruments TCM4300 User Manual

Page 18

background image

2–3

2.4.3

Terminal Impedance

FUNCTION

MIN

TYP†

MAX

UNIT

Receive channel input impedance (single ended), RXIP/N and RXQP/N

40

70

k

Transmit channel output impedance (single ended), TXIP/N and TXQP/N

40

50

100

FM input impedance, WBD

25

200

k

MCLKOUT impedance

MCLKOUT at 3.3 V

240

MCLKOUT impedance

MCLKOUT at 5 V

180

† All typical values are at DVDD = 5 V, AVDD = 5 V, and TA = 25

°

C, unless otherwise specified.

2.4.4

RXIP, RXIN, RXQP, and RXQN Inputs (AV

DD

= 3 V, 4.5 V, 5 V)

PARAMETER

TEST CONDITIONS

MIN

TYP

MAX

UNIT

Input voltage range

0.3

AVDD– 0.3

V

Input voltage for full-

Differential

0.5

Vp-p

Input voltage for full
scale digital output

Single ended

0.5

Vp-p

Nominal operating

Differential

0.125

Vp p‡

Nominal operating
level

Single ended

0.125

Vp-p‡

Input CMRR (RXI, RXQ)

45

dB

Sampling frequency, SINT (digital
mode)

48.6

kHz

Sampling frequency, SINT (analog
mode)

40

kHz

Receive error vector magnitude (EVM)

5%

6%

I/Q sample timing skew

Input signal 0 – 15 kHz

50

ns

A / D resolution

10

bits

Signal to noise-plus distortion

Input at full scale – 1 dB

54

58

dB

Integral nonlinearity

0 dB to – 60 dB input

1

LSB

Gain error (I or Q channel)

±

7%

Gain mismatch between I and Q

±

0.3

dB

Differential dc offset voltage

±

30

mV

FM input sensitivity, full scale
(

14 kHz deviation)

2.5

Vp-p

FM input dc offset (relative to VHR)

±

80

mV

FM input idle channel noise, below
full-scale input

– 50

dB

FM gain error

±

6%

Power supply rejection

f = 0 kHz to 15 kHz

40

dB

‡ Provides 12 dB headroom for AGC fading conditions.