Quantum Audio Travan 40 Tape Drive STT3401A User Manual
Page 47
ATAPI Interface
Chapter 5
Seagate Travan 40 Product Manual
Page 39
D
Parameter Code
LSB
01
E
DU
DS
TSD
ETC
TMC
0
LP
40
F
Parameter Length
04
10
11
12
13
MSB
Total Errors Corrected
LSB
XX
XX
XX
XX
NOTE: (Total Blocks Recovered by ECC) + Total Errors Corrected = Total Blocks Read
Page 03—Error Counter for READ definitions
Byte
00
Page Code
Set to 03h.
01
Reserved
Set to 00h.
02-03
Additional Page Length
Set to 1Ch.
04-05
Parameter Code
0000h—# of block recovered by ECC alone
0001h—# of blocks recovered without using ECC
0002h—total # of rereads
0003h—total errors corrected
0004h—# of frames corrected by ECC alone
0005h—total # of bytes processed
8004h—total # of bytes corrected by ECC
06
DU
The Disable Update bit is always set to 0, indicating the drive
updates parameter values for all events.
DS
The Disable Save bit is always set to 1, indicating the drive
does not save parameter values.
TSD
The Target Save Disable bit is always set to 0 indicating the
drive defines a method for saving log parameters.
ETC
The Enable Threshold Comparison bit is always set to 0,
indicating comparison to the threshold value is not performed
whenever the cumulative value is updated.
TMC
The Threshold Met Criteria bits are used with the ETC bit and
are always set to 0.
LP
The List Parameters bit is always set to 0, indicating all
parameters are data counters.
07
Parameter Length
Set to 02h, indicating 2 bytes in the counter.
08-09
Total Re-Reads
(*)
Total number of uncorrectable frames. An uncorrectable
frame will generate a Re-Read recovery sequence.
…
0E-10
Total Errors Corrected
(*)
Total number of frames corrected is the sum of the number of
frames corrected by ECC plus the number of frames corrected
by the Re-Read recovery procedure.
…
15-16
Frames Corrected By
ECC Alone
(*)
The total number of frames containing one or more blocks that
failed the CRC check. For the total number of blocks, see
REQUEST SENSE.
…
1B-1F
Total Bytes Processed
(*)
The transfer length of all Fixed Block Mode READ commands
times the block length specified in Mode Data plus the total
transfer length of all Variable Block Mode READ commands.
…
1B-1F
Total Bytes Corrected
by ECC
(*)
The total number of bytes corrected by ECC during all READ
commands.