beautypg.com

Quantum Audio Travan 40 Tape Drive STT3401A User Manual

Page 108

background image

Chapter 5

ATAPI Interface

Page 100

Seagate Travan 40 Product Manual

Word(s)

Starting Offset

(hex)

Description of Contents

Value (hex)

49

62

Capabilities:
15 1=interleaved DMA support
14 1=command queuing supported
13 1=overlap operation supported
12 1=ATA software reset required (obsolete)
11 1=IORDY supported (must be set if device supports
PIO mode 3 or higher)
10 1=IORDY may be disabled (via the SET FEATURES
command)
9 1=LBA supported
8 0=DMA supported
7-0 vendor specific

0A00

50

64

reserved

0000

51

66

15-8 PIO data transfer mode number
00h PIO mode 0
01h PIO mode 1
02h PIO mode 2
03h-FFh reserved
7-0 vendor specific

0200

52

68

reserved

0000

53

6A

Indicates which optional words are valid:
15-3 reserved
2 1=the fields reported in word 88 are valid
1 1=the fields reported in words 64-70 are valid
0 1=the fields reported in words 54-58 are valid

0002

54-62

6C

reserved for ATA devices

0000

63

7E

Only one mode may be selected at a time. If an UltraDMA mode is selected,
then bits 15-8 must be 0.
multiword DMA transfer MODE SELECTed
15-11 reserved
10 1=multiword DMA mode 2 is selected
9 1=multiword DMA mode 1 is selected
8 1=multiword DMA mode 0 is selected
multiword DMA transfer modes supported
7-3 reserved
2 1=multiword DMA mode 2 is supported
1 1=multiword DMA mode 1 is supported
0 1=multiword DMA mode 0 is supported

0000

64

80

15-8 reserved
advanced PIO transfer modes supported
7-2 reserved
1 1=PIO mode 4 is supported
0 1=PIO mode 3 is supported

0002

65

82

15-0 minimum multiword DMA transfer cycle time per word (nanosecs)
multiword DMA mode 2: 120 = 0078h
multiword DMA mode 1: 150 = 0096h
multiword DMA mode 0: 480 = 01E0h

***01E0

66

84

15-0 manufacturer’s recommended multiword DMA transfer cycle time
(nanosecs)

01E0

67

86

15-0 minimum PIO transfer cycle time without IORDY flow control (nanosecs)
PIO mode 4: 120 = 0078h
PIO mode 3: 180 = 00B4h
PIO mode 2: 240 = 00F0h
PIO mode 1: 383 = 017Fh
PIO mode 0: 600 = 0258h

00B4

68

88

15-0 minimum PIO transfer cycle time with IORDY flow control (nanosecs)

00B4

69-70

8A

reserved

0000