beautypg.com

Quantum Audio Travan 40 Tape Drive STT3401A User Manual

Page 20

background image

Chapter 4

Drive operation and maintenance

Page 12

Seagate Travan 40 Product Manual

Before installing the Seagate Travan 40 drive make sure that the jumpers are
properly configured for your system. Figure 6 shows the location of the jumper block,
as well as master/slave jumper settings for various configurations.

Note: Record your jumper settings prior to installation. The jumpers are not visible

after the drive has been installed.

Figure 6
Jumper block settings for STT3401A and ST2401A

These jumper settings are explained in further detail below.

Jumpers 1 and 2 are reserved for factory use. Do not install a jumper on these
pins.

Cable Select: When the CSEL jumper is off, the device address (Master or
Slave) is determined by the setting of the "Master" jumper. When the CSEL
jumper is on, the Master jumper is ignored and the device address is defined by
the CSEL signal in the Host cable. If CSEL is tied to ground, the device address
is Device 0 (Master). If the signal is tied high (or open), the device address is
Device 1 (Slave).

Master/Slave: When this jumper is on, drive will act as Master on the ATA port.
An ATAPI device cannot be a Master to an ATA device, only other ATAPI
devices. If there is no jumper on the Master or CSEL jumper blocks, the drive is
configured as a slave. See table below:

"CSEL"
jumper block

"Master"
jumper block


Drive's master/slave setting

Off

On

Device is Master (Device 0)

Off

Off

Device is Slave (Device 1)

On

On or Off

Device is Master or Slave depending
on CSEL signal level

This manual is related to the following products: