Chapter 4
Drive operation and maintenance
Page 22
Seagate Travan 40 Product Manual
1
DRAM Write Miscompare
2
DRAM Write Timed Out
3
DRAM Read Timed Out
4
DMA Timed Out
5
ATAPI Interface Failed
6
SRAM Self Test Failed
7
DRAM/SRAM Self Test Failed
8
Serial ASIC Failed
9
Buffer Manager ASIC Failed
11
Stepper Motor Test Failed
12
Transport Motor Test Failed
15
Attempt to install incompatible firmware
16
Transfer timeout
17
Load operation failed
Drive does not come ready
•
Insure the cartridge is properly oriented and fully inserted.
•
Insure the cartridge is not broken and the tape appears in good condition.
Motor starts to drive cartridge but stops immediately
Check the cartridge for tape run-off, or excessive torque. Replace cartridge if
required.
Drive will not write but will read previously written tapes
•
Make sure the cartridge is not write-protected.
•
Make sure the cartridge is a Travan 40 cartridge, not a Travan 5 or older Travan
cartridge.
•
Verify proper cable attachment to the host PC.
•
If this does not correct the problem, contact Seagate Technical Support (see
page 21).
Tape does not stream
Host data handshake may be too slow. Check BIOS setting for ATAPI interface
mode; the interface chipset may not be capable of high speed PIO mode. Some
backup application software is capable of higher transfer rates than others. Other
Host activity could restrict backup operation transfer rate.
If a power interruption occurs during a backup or restore operation, start over when
the power is restored.