Name, Bar code names, Field options – O'Neil microFlash Series User Manual
Page 80: Bar code field options
70
•
Custom Receipts and Labels User Manual and Technical Guide The O'Neil microFlash Series of Printers
{Print,
Global options:@row,column:
Name
,Field Options|data|}
Bar Code Names
Name
Description
Requirements for Data
BC39N
Code 39 2:1 ratio
Can use these characters in the data field:
Space $ % + . / 0-9 A - Z
Auto inserts leading and trailing “*”
BC39W
Code 39
3: 1 ratio
Can use same characters as above
COBAR
Codabar
0-9 - $ : / . + a b c d, user must send leading and trailing
guard bar a-d
I2of5
Int. 2 of 5
2.5:1 ratio
0-9 (digits only, must be even. Controller will insert leading
zero to assure an even number of digits)
BCI25
Int. 2 of 5
2:1 ratio
0-9 (digits only, must be even. Controller will insert leading
zero to assure an even number of digits)
BC128
Code 128
Automatically selects Codes A - C, for the shortest bar code.
Allows all ASCII characters.
EN128
EAN-128
Uses Codes C, for the shortest bar code. Allows all ASCII
characters.
UPC-A
UPC-A
0-9 (must have 11 digits or error, controller calculates check
digit)
EAN08
EAN-8
0-9 (must have 7 digits or error, controller calculates check
digit)
EAN13
EAN-13
0-9 (must have 12 digits or error, controller calculates check
digit)
PD417
PDF-417
See Notes on the use of PDF-417
{Print,Global Options1:@row,column:Name,
Field Options
|Data|}
Bar Code Field Options
Field
Option
Abbr.
Description
HIGHn
Hn
Changes height of bar code in 5 dot inch intervals; default
is 5 dots; 1 < n < 255.
WIDEn
Wn
Width multiplier of bar code; default is 1; W=2 is twice as
wide (1/2 density) as W = 1; 1 < n < 255.