Oki 6E User Manual
Page 113

6 - 13
Category
Controller errors
ERROR nn
Error
Remedy
LCD status message
Trouble or status
Remedy
– Check the optional RAM board
for proper connection.
– Check the mounting position of
short plugs and additional RAM
chips (see 7.4).
– Replace the option RAM board.
60
An error was detected by
optional RAM check.
– Check the fan motor for proper
connection and for any presence
of foreign matter in the fan (see
6.5.2-
5
).
– Replace the fan or the Main
Control PCB.
70
A fault occurred in the Fan
motor.
See 6.5.2-
4
.
71
A fault occurred in the fuser
(timeout error etc.).
See 6.5.2-
4
.
72
A fault occurred in the fuser
(thermistor open error).
See 6.5.2-
4
.
73
A fault occurred in the fuser
(thermistor short error).
Replace the power supply board
or the Main Control PCB.
74
Power supply board SSIO
I/F error
– Check the operator panel for
proper connection.
– Replace the flexible cable,
operator panel or Main Control
PCB.
80
I/F timeout occurred between
the Main Control PCB and
the operator panel.
Code
(nn)
Table 6-2 (Cont'd)