Advanced screens, Mate screens, Page 52 – Outback Power Systems FX 2012T User Manual
Page 52: Password code
Installation & Programming Manual
FX & VFX Series Inverter/Charger System
Copyright 2003
OutBack Power Systems, Inc.
900-0027-1
19009 62
nd
Ave NE, Arlington WA 98223 USA
Page 52
Rev 7.2
08/26/05 Tel 360 435 6030 Fax 360 435 6019
MATE SCREENS
Advanced Screens
The ADVANCED menu section allows adjustment of all the settings involved with the operation of the FX. Changes made to these
settings are stored internally in non-volatile memory inside of the FX – the settings are not lost when the MATE is removed or battery
power is disconnected.
Some settings appear both in the SETUP and in the ADV menus. Changes made to these settings in one area will cause the same
changes to occur in the other area. The settings are provided in both menus to make it more convenient for the FX programmer by
giving access to all of the settings in the advanced menu.
Access to the settings in the advanced menu is restricted through the use of a password. This password is required to view and adjust
the settings. Once the password has been entered, all ADVANCED categories can be adjusted without having to re-enter the
password. If the advanced menu is exited and re-entered, the password must be re-entered, however. Use of the “Hot” keys AC IN
and INV is allowed from the advanced menu and selecting OK from these screens will return you to the same point in the advanced
menu.
The password for the FX is currently fixed to the same value for all of the FX’s.
PASSWORD CODE:
1 4 1
MAIN----------------
6:54:42P
SUM STATUS SETUP ADV
↓
ADV/SETTINGS/WARNING
changes made could
adversely effect
system performance
↓
↓
↓
↓
ADV/PASSWORD--------
enter the password:
132
ENTER INC
DEC
EXIT
↓
ADV-----------------
choose product:
FX
MX
MATE
MAIN
↓
ADV/FX/PAGE1--------
choose category:
ADV
INV
CHGR
PG2
↓
ADV/FX/PAGE2--------
choose category:
PG1
GRID
GEN
PG3
↓
ADV/FX/PAGE3--------
choose category:
PG2
AUX
STACK
PG4
↓
ADV/FX/PAGE3--------
choose category:
PG3
SELL
CAL
MAIN
The MAIN screen is where the menu system starts. The four words in the bottom line of the display
correspond to the four buttons located below the display. The word in BOLD on the bottom line
indicates the selection used to advance the display to the next screen. Pressing the left two buttons
simultaneously from anywhere in the menu will return you to this screen.
Selecting
keys below the display advances the display to the password screen.
Entering the correct password
number is done by pressing the
or the
(141)
, press the key below the word
any changes, press EXIT.
Following the password screen is a screen that allows selection of the OutBack product type.
Selecting
access to the advanced sections of any MX-60’s connected to the system (through a HUB). Selecting
MATE will allow access to the MATE’s advanced screens. Selecting MAIN returns the user to the
MAIN menu.
There are eight categories of settings in the FX:
INV
Allows adjustment of the INVERTER settings and operation
CHGR
Allows adjustment of the CHARGER settings and operation
GRID
Allows adjustment of the AC input settings and operation if the FX’s input is set to GRID
in the SETUP/FX/INPUT “ac transfer control” screen (see previous page)
GEN
Allows adjustment of the AC input settings and operation if the FX’s input is set to GEN in
the SETUP/FX/INPUT “ac transfer control” screen (see previous page)
AUX
Allows adjustment of the AUXILIARY output settings and operation
STACK
Allows adjustment of the master/slave settings for multi-FX systems
SELL
Allows adjustment of the Grid-Tie settings and operation
CAL
Allows adjustment of the voltage calibration measurements to improve operation
Selecting ADV will send the user back one screen to the “choose product” screen in the advanced
menu. PG2 will advance the user to page 2 of the advanced menu. PG3 will advance the user to
page 3 of the advanced menu. PG4 will advance the user to page 4 of the advanced menu.