Part 3 - keypad configuration – Omega FD6003 User Manual
Page 30

3-14
Third press
Restarts the internal 
totalizer/external CTR 
(The internal totalizer starts 
from zero.) 
(continued)
If inhibiting (pausing) the totalizer is necessary, there are 
two methods suggested: 
1. Connect and external totalizer to the CTR terminals.
See the section of this manual related to CTR 
electrical connections for connection parameters. 
2. To inhibit the internal totalizer without resetting the
accumulation, press the TEST key to pause the 
accumulation. Press the ENTER key to resume 
accumulation. 
LOCK ON
To ensure security of the configuration and accumulated 
flow, the keypad can be locked. To enable the keyboard 
lock out, press LOCK ON key, the display will show 
LOCK ON. Press ENTER to return to Run mode. To 
turn the lock off, press the LOCK ON key. Use the arrow 
keys to set a value of 125. Press the ENTER key. The 
display will show LOCK OFF to acknowledge that all 
keypad entries can now be made. 
CAL
A few factors can influence the readings of a FD6000 
flow meter. The CAL entry allows the user to compensate 
for flow discrepancies without affecting the factory 
calibration. Examples of situations that can cause 
reading discrepancies are: 
n Operations on liquids with sonic velocity carrying
properties that are different from water. See the table
PART 3 - KEYPAD CONFIGURATION