Appendices

In the upper range,

the sound changes

abruptly beyond a

certain key

On an acoustic piano, notes in the upper one
and a half octaves of the keyboard continue to
sound until they decay naturally, regardless of
the damper pedal. There is a difference in the
timbre as well. Roland pianos faithfully simu-
late such characteristics of the acoustic piano.
On the HP-7/3, the range that is unaffected by
the damper pedal will change depending on
the Key Transpose setting.

A High-pitched

whine is produced

When listening through headphones:

Some of the more flamboyant and efferves-
cent piano tones feature an ample high-end
component, which may make the sound
appear to have metallic reverberation add-
ed. Since this reverberation becomes par-
ticularly audible when supplemented by
heavy reverb, you may be able to diminish
the problem by reducing the amount of re-
verb applied to the sound.

When listening through speakers:

Here, a different cause (such as resonance
produced by the HP-7/3) would be sus-
pect. Consult your Roland dealer or near-
est Roland Service Center.

Case

Cause/Remedy

The bass range

sounds odd, or

there is a vibrating

resonance

When listening through speakers:

Playing at loud volumes may cause instru-
ments near the HP-7/3 to resonate. Reso-
nation can also occur with fluorescent light
tubes, glass doors, and other objects. In
particular, this problem occurs more easily
when the bass component is increased, and
when the sound is played at higher vol-
umes. Use the following measures to sup-
press such resonance.
• Place speakers so they are 10–15 cm from

walls and other surfaces.

• Reduce the volume.
• Move the speakers away from any reso-

nating objects.

When listening through headphones:

Here, a different cause (such as resonance
produced by the HP-7/3) would be sus-
pect. Consult your Roland dealer or near-
est Roland Service Center.

The volume level of

the instrument con-

nected to Input

jacks is too low

Could you be using a connection cable that
contains a resistor?
Use a connection cable that does not contain a
resistor.

Case

Cause/Remedy

Error Messages/Other Messages

*

Error messages are indicated by an “E.” before the number. Press any button, and you can cancel the error message.

Display

Meaning

USr

User. Stores recorded performances (p. 28).

Usr.

The “.” in the display indicates that there is performance material already re-
corded (p. 28).

d.

Built-in song number (p. 13).

r.

Rhythm number (p. 20).

PU

This appears when a song with a pickup (a song that does not start on the first
beat) is played back.

dEL

This appears when you attempt to delete a recorded song (p. 27, p. 32).

E.32

The amount of performance information is too large, and further recording is
not possible.

E.41

A problem such as a loose MIDI cable occurred. Make sure the MIDI cables
are correctly hooked up.