FPI P36-4 Zero Clearance Direct Vent Gas Fireplace

57

TRIPOLI SCREEN DOOR

REGENCY

®

OPTIONS

When installing the optional Tripoli Screen Door Series, a non-combustible material 12" (305mm) above the unit and 6" (153mm)
on each side must be used (see Diagram 1).

The Tripoli Screen Door Series also requires steel stud framing above and on each side of the unit (refer to Diagram 1).

Option #2:

Fireplace with 1" (25mm) Facing Material

Diagram 1

Option #1:

Fireplace with 1-1/2" (38mm) Facing Material

INSTALLATION NOTE:

The hearth material must be brought past the Tripoli frame all the way to the unit

face, so there will be no gap between the face and the actual fi replace.

* 'D' is Minimum height to combustible materials including the Minimum 2" (51mm) Top clearance to the Horizontal Vent.

OPTIONS

FRAMING DIMENSIONS

P36

P36D

A

B

C

D

A

B

C

D

1

36-1/4”

(921mm)

36-1/4”

(921mm)

14-1/4”

(362mm)

46”*

(1168mm)

36-1/4”

(921mm)

36-1/4”

(921mm)

18-5/8”

(473mm)

46”*

(1168mm)

2

36-1/4”

(921mm)

36-1/4”

(921mm)

13-3/4”

(349mm)

46”

(1168mm)

36-1/4”

(921mm)

36-1/4”

(921mm)

18-1/8”

(460mm)

46”

(1168mm)