FPI P36-4 Zero Clearance Direct Vent Gas Fireplace

22

Rigid Pipe Adaptor

Pipe Length

Vertical

Termination

Cap

Storm Collar

Flashing

Ceiling Firestop

24" Pipe

Length

Adj.Pipe Length

11" - 14-5/8"

90 Elbow

o

Horizontal

Termination

Cap

Wall Thimble

Vinyl Siding

Standoff (Optional)

RIGID PIPE VENTING SYSTEMS

Horizontal or Vertical Terminations

The minimum components required for a basic horizontal termination are:

1 Horizontal

Termination

Cap

1 90

o

Elbow

1 Rigid

Pipe

Adaptor

1 Wall

Thimble

1 Length of pipe to suit wall thickness (see chart)

Wall thickness is measured from the back standoffs to the inside mounting
surface of termination cap. For siding other than vinyl furring strips may be
used, instead of the vinyl siding standoff, to create a level surface to mount the
vent terminal. The Terminal must not be recessed into siding. Measure the wall
thickness including furring strips.

Alternate

Horizontal Ter-

mination Caps

(Must be used with all Rigid Piping)

Flat Wall Installation

Wall Thickness

(inches)

Vent Length Required

(inches)

4" - 5-1/2"

6"

7" - 8-1/2"

9"

10" - 1-1/2"

12"

9" - 14-1/2"

11" - 14-5/8" Adj. Pipe

15" - 23-1/2"

17" - 24" Adj.

Corner Installation

Wall Thickness

(inches)

Vent Length Required

(inches)

3-1/4" - 6-3/4"

11" - 14-5/8" Adj. Pipe

7-3/4" - 16-1/4"

17" - 24" Adj. Pipe

7-1/4" - 8-3/4"

6" + 12"

9" + 9"

4-1/4" - 5-3/4"

6" + 9"

This product has been evaluated by Intertek for
using a Rigid Pipe Adaptor in conjunction with
Duravent Direct-Vent GS, Selkirk Direct-Temp,
Ameri Vent Direct venting and Security Secure
Vent systems. Use of these systems with the
Rigid Pipe adaptor is deemed acceptable
and does not affect the Intertek WHI listing of
components.

WARNING:

Do not combine venting components from
different venting systems.

However use of the the AstroCap

TM

and FPI

Riser is acceptable with all systems.

When using Rigid Vent other than

Simpson Dura-Vent, 3 screws must be

used to secure rigid pipe to adaptor.

The FPI AstroCap

TM

and FPI Riser Vent terminal are certifi ed for installations using FPI venting systems as well as Simpson Dura-Vent

®

Direct Vent GS,

American Metal Products Ameri Vent Direct Vent, Security Secure Vent

®

, Selkirk Direct-Temp. AstroCap

TM

is a proprietary trademark of FPI Fireplace

Products International Ltd. Dura-Vent® and Direct Vent GS are registered and/or proprietary trademarks of Simpson Dura-Vent Co. Inc.

INSTALLATION

This manual is related to the following products: