FPI P36-4 Zero Clearance Direct Vent Gas Fireplace

33

GAS LINE

INSTALLATION

The gas line is brought through the right of the
appliance. The gas valve is situated on the right
hand side of the unit and the gas inlet is on the
right hand side of the valve.

The gas line connection may be made of rigid
pipe, copper pipe or an approved fl ex connector.
(If you are using rigid pipe, ensure that the valve
can be removed for servicing.) Since some
municipalities have additional local codes it is
always best to consult with your local authorities
and the CAN/CGA B149 installation code.

For USA installations follow local codes and/or
the current National Fuel Gas Code, ANSI
Z223.1.

When using copper or fl ex connectors use only
approved fi ttings. Always provide a union so
that gas lines can be easily disconnected for
servicing. Flare nuts for copper lines and fl ex
connectors are usually considered to meet this
requirement.

Important: Always check for gas leaks with a
soap and water solution or gas leak detector.
Do not use open fl ame for leak testing.

P36-NG4 System Data

For 0 to 4500 feet altitude
Burner Inlet Orifi ce Sizes: #37

Max. Input Rating: 30,000 Btu/h
Min. Input Rating: 15,300 Btu/h

Output Capacity with blower Off:

22,600

Btu/h

Output Capacity with blower On:

23,000

Btu/h

Minimum Output with blower Off:

11,500

Btu/h

Supply Pressure: min.5.0"

w.c.

Manifold Pressure
(High):
3.8"+/-

0.2"w.c.


Electrical: 120 V A.C. System.
Circulation Fan: variable speed 130 CFM.
Log Set: Ceramic fi bre, 7 per set.
Vent System: Simpson Dura-Vent Direct
Vent System or FPI Direct Vent System
(Flex)

Note: Output capacity:

The

effi ciency rating of the appliance

is a product thermal efficiency
rating determined under continuous
operating conditions and was
determined independently of any
installed system.

Vent height may or may not change

your effi ciency ratings.

HIGH ELEVATION

This unit is approved in Canada for altitude 0
to 4500 ft. (CAN1 2.17-M91) with the orifi ce
supplied.

P36-LP4 System Data

For 0 to 2000 feet altitude
Burner Inlet Orifi ce Sizes:

#52

Max. Input Rating 30,000 Btu/h
Min. Input Rating

15,000 Btu/h

Output Capacity with blower Off

22,800

Btu/h

Output Capacity with blower On

23,200

Btu/h

Minimum Output with blower Off

11,700

Btu/h

For 2000 to 4500 feet altitude
Burner Inlet Orifi ce Sizes:

#53

Max. Input Rating 25,000 Btu/h
Min. Input Rating

12,600 Btu/h

Output Capacity with blower Off

19,000

Btu/h

Output Capacity with blower On

19,300

Btu/h

Minimum Output with blower Off

11,700

Btu/h

For 0 to 4500 feet Altitude:

Supply Pressure min.12.0"

w.c.

Manifold Pressure
(High)

11"+/- 0.2" w.c.

Electrical: 120 V A.C. System.
Circulation Fan: variable speed 130 CFM.
Log Set: Ceramic fi bre, 7 per set.
Vent System: Simpson Dura-Vent Direct
Vent System or FPI Direct Vent System
(Flex)

INSTALLATION