Page 43: Wall thermostat (optional)

background image

FPI P36-4 Zero Clearance Direct Vent Gas Fireplace

43

REMOTE CONTROL

(OPTIONAL)

Use the FPI Remote Control Kit approved for
this unit. Use of other systems may void your
warranty.

The remote control kit comes with a hand held
transmitter, a receiver and a wall mounting
plate.

1) Choose a convenient location on the wall

to install the receiver and the receptacle
box (protection from extreme heat is very
important). Run wires from the fi replace
to that location. Use the Thermostat Wire
Table.

2) Connect the two wires to the gas valve. See

diagram below.

CAUTION

Do not connect millivolt

remote control wires

to 120V wire.

3) Install 3 AAA alkaline batteries in transmitter

and 4 AA alkaline batteries in the receiver.
Install the receiver and its cover in the wall.
Switch the remote receiver to "remote"
mode. The remote control is now ready for
operation.

WALL SWITCH

(OPTIONAL)

1) Run the wire through the right or left side

inlet opening. Be careful not to damage
wire.

Note: We recommend a maximum of 15'

of wire but if you wish to go with a
longer run, use the Thermostat Wire
Table.

2) Connect the wire to the wall switch and install

into the receptacle box. See the "Alternate
Wiring Diagram for Wall Switch" section for
wiring diagrams.

CAUTION

Do not connect millivolt

wall switch wire

to 120V wire.

14 GA.
16 GA.
18 GA.
20 GA.
22 GA.

50 Ft.
32 Ft.
20 Ft.
12 Ft.

9 Ft.

Recommended Maximum Lead Length

(Two-Wire) When Using Wall

Thermostat (CP-2 System)

Wire Size Max. Length

Thermostat Wire Table

WALL THERMOSTAT

(OPTIONAL)

A wall thermostat may be installed if desired,
connect the wires as per the wiring diagram.
Use the table below to determine the maximum
wire length.

Note: Preferable if the thermostat is

installed on an interior wall.

FPI offers an optional programmable thermostat
but any 250-750 millivolt rated non-anticipator
type thermostat that is CSA, ULC or UL approved
may be used.

CAUTION

Do not connect millivolt

wall thermostat wires

to 120V wire.

INSTALLATION