This chapter describes how to troubleshoot when this product does not work properly.

5.1 Flowchart to Remedy the Troubles

Figure 5.1 shows the flowchart to remedy the troubles from when power to the emulator is activated until the emulator
debugger starts up. Check this while the user system is disconnected. For the latest FAQs visit the Renesas Tools Homepage.

http://www.renesas.com/en/tools


Figure 5.1 Flowchart to remedy the troubles

Turning on emulator

Front panel LED

of emulator

1. Check connection of the power supply cable.

See 2.5 Connecting the Power Supply for the Emulator (page 23).

2. Check that the power is properly supplied to the user system.

See

Turning ON the Power (page 24).

Init dialog box of emulator

debugger displayed

1. Check the operating environment etc. of the emulator debugger.

See the users manual of the emulator debugger.

2. Reinstall the emulator debugger.

EMEM dialog box of

emulator debugger

See 5.2 (2) EMEM Dialog Box Does Not Appear at Debugger Startup
(page 97).

Program window of emulator

debugger displayed

See 5.2 (3) Errors Occur at Debugger Startup (page 98).

Emulator debugger startup completed

Normal

Normal

Normal

Normal

Not normal

Not normal/Error displayed

Not normal/Error displayed

Error displayed