beautypg.com

Renesas Emulation Probe for M32C/87 Group M30870T-EPB User Manual

Page 68

background image

M30870T-EPB User’s Manual

3. Usage (Emulator Debugger)

REJ10J0482-0300 Rev.3.00 February 16, 2006


(3) When DATA ACCESS is selected

1. Window for setting the address


2. Window for setting data

Setting the address

You can set eight conditions, e.g., a specified address, a

specified address range, etc.

Setting data

You can set eight conditions, e.g., a specified data, a

specified data range, etc.

Setting the access condition

You can set three conditions, e.g., read, write, and

read/write. When you have finished setting the data and

access condition, click OK.

Page 68 of 104