beautypg.com

3 switches – Renesas M34502T-MCU User Manual

Page 17

background image

( 15 / 38 )

4.3 Switches

Figure 4.3 shows the positions of switches of the M34502T-MCU. Table 4.2 lists the functions of the
switches and their factory-settings.

Figure 4.3 Positions of switches

Table 4.2 Functions of switches

The M34502T-MCU operates for 4501,
4502, 4506 and 4507 Groups.

The M34502T-MCU operates for 4580
Group.

Outputs the V

DD

of the M34502T-MCU to

the target system.

Set the MCU’s ROM size.
• Set "2" for M2
• Set "4" for M4

Does not output the V

DD

of the M34502T-

MCU to the target system.

OFF

ON

SW1

OFF

ON

Label

Setting

Description

Factory-setting

Switch

OFF

ON

ROMSIZE

SW2

SW3

5 V

3 V

3 V

5 V

3 V

5 V

Operates the evaluation MCU on the
M34502T-MCU at +5 V.

Operates the evaluation MCU on the
M34502T-MCU at +3 V.

OFF

Set to "4"

580

501/502

580

501/502

501/502

580

SW4

501/502

5 V