Ricoh INFOPRINT XT GLD0-0025-01 User Manual
Page 158

the
COLLATE
DJDE
in
the
input
file
and
reconvert
the
job.
AIOxxx563W
The
data
stream
converter
ignored
an
incorrect
COLLATE
change
request.
Explanation:
The
COLLATE
DJDE
that
InfoPrint
XT
found
is
not
valid
after
the
first
data
record
of
the
report.
System
action:
InfoPrint
XT
continues
processing
the
job.
User
response:
Make
sure
of
the
correct
placement
of
the
COLLATE
DJDE
in
the
input
file
and
reconvert
the
job.
AIOxxx564E
djde_name
-
DJDE
value
value
is
not
valid
for
the
specified
conversion
units.
Explanation:
InfoPrint
XT
cannot
process
the
value
value
correctly.
For
units
such
as
IN
(inches)
or
CM
(centimeters),
InfoPrint
XT
expects
no
more
than
three
decimal
places.
For
DOTS,
InfoPrint
XT
expects
an
integer
value.
System
action:
InfoPrint
XT
continues
processing
the
job,
but
the
output
might
not
be
correct.
User
response:
Round
any
decimal
values
to
three
decimal
places,
or
supply
integer
values
for
DOTS.
AIOxxx565E
djde_name
-
DJDE
value
input
is
not
valid
for
a
numeric
entry
field.
Explanation:
InfoPrint
XT
cannot
process
the
value
input
correctly.
InfoPrint
XT
does
not
process
the
DJDE
(djde_name).
DJDE
naming
conventions
require
a
numeric
entry
with
specific
rounding
values.
System
action:
InfoPrint
XT
continues
processing
the
job,
but
the
output
might
not
be
correct.
User
response:
Correct
the
value
and
reconvert
the
job.
AIOxxx566E
DJDE_keyword
—
DJDE
option_name
is
not
valid.
Explanation:
The
option_name
option
of
the
DJDE_keyword
DJDE
is
not
valid.
System
action:
InfoPrint
XT
ignores
the
DJDE
keyword
and
continues
processing.
User
response:
Correct
the
DJDE
and
reconvert
the
job.
AIOxxx567E
The
data
stream
converter
found
an
incorrect
copy
sensitive
change
request.
Explanation:
A
copy-sensitive
MODIFY,
FORMS,
or
BFORM
change
request
was
made
during
the
processing
of
the
current
report.
You
can
only
specify
copy-sensitive
MODIFY,
FORMS,
and
BFORM
commands
at
the
beginning
of
a
report.
The
program
ignores
the
request.
After
text
has
printed
on
a
copy-sensitive
report,
you
can
only
change
a
MODIFY,
FORMS,
or
BFORM
command
to
NONE.
System
action:
InfoPrint
XT
continues
processing
the
job,
but
the
output
might
not
be
correct.
User
response:
Correct
the
request
that
was
made
after
the
beginning
of
the
report
and
reconvert
the
job.
AIOxxx568E
The
data
stream
converter
could
not
find
graphic
image
resource_name
in
the
image
correlation
table
and
did
not
process
the
command
DJDE
command.
Explanation:
The
named
resource,
resource_name,
was
not
found.
The
resource
name
might
be
misspelled.
The
resource
might
not
be
loaded
on
the
InfoPrint
XT
server
or
it
might
have
been
loaded
as
a
resource
that
belongs
to
a
specific
resource
group.
System
action:
InfoPrint
XT
continues
processing
the
job,
but
the
output
might
not
be
correct.
User
response:
Check
the
spelling
of
the
resource
name.
Make
sure
that
the
resource
has
been
loaded
either
as
a
shared
resource
or
as
a
resource
that
belongs
to
a
specific
resource
group.
Then,
reconvert
the
job.
AIOxxx569E
The
data
stream
converter
found
incorrect
DJDE
command
command.
Explanation:
The
listed
command
(command)
is
not
a
known
DJDE
command,
or
its
specification
or
format
is
not
correct.
The
program
might
not
process
the
input.
System
action:
InfoPrint
XT
might
not
continue
to
process
the
job.
User
response:
Correct
the
command
and
reconvert
the
job.
For
SHIFT
or
XSHIFT
DJDEs
that
are
not
valid,
the
previous
front
or
back
side
SHIFT
or
XSHIFT
value
might
remain
in
effect.
The
DJDE
report
provides
details.
AIOxxx573W
Graphic
image
image_name
is
not
active.
The
data
stream
converter
did
not
process
the
command
command.
Explanation:
The
data
stream
converter
did
not
find
graphic
image
image_name
before
it
found
the
ALTER
or
CANCEL
command
for
the
image.
System
action:
InfoPrint
XT
might
not
continue
to
process
the
job.
User
response:
Correct
the
original
Xerox
job
so
that
it
uses
the
syntax
rules
for
graphic
images.
Then,
reconvert
the
job.
138
InfoPrint