3 trace functions – Renesas SuperH SH7600 Series User Manual
Page 24
18
Table 2.5 lists the combinations of conditions that can be set under Break Condition 1, 2, 3.
Table 2.5 Dialog Boxes for Setting Break Conditions
Type
Dialog Box
Address Bus
Condition
(Address)
Data Bus
Condition
(Data)
Bus State
Condition
(Bus Status)
Count
Condition
(Count)
Internal
I/O Break
[Break Condition 1]
dialog box
O
O
O O
X
[Break Condition 2]
dialog box
O
X
O
X X
[Break Condition 3]
dialog box
X X X
X
O
Note: O: Can be set in the dialog box.
X: Cannot be set in the dialog box.
2.2.3 Trace
Functions
The SH7630 E10A emulator supports the trace functions listed in table 2.6.
Table 2.6 Trace Functions
Function
Internal Trace
AUD Trace
Branch trace
Supported (eight branches)
Supported
Range memory access trace
Not supported
Supported
Software
trace
Not
supported Supported
Table 2.7 shows the type numbers that the AUD function can be used.
Table 2.7 Type Number and AUD Function
Type Number
AUD Function
HS7630KCM01H, HS7630KCI01H
Not supported
HS7630KCM02H, HS7630KCI02H
Supported