Installation and operation, Dip switch settings, A.3 installation and operation – RAD Data comm 4-Wire Symmetrical VDSL Modem ASM-60 User Manual
Page 49
ASM-60 Installation and Operation Manual
Appendix A IR-ETH Interface Module
Installation and Operation
A-3
A.3 Installation and Operation
shows the Ethernet bridge layout, the location of the DIP switch, and
the rear panel components of the IR-ETH interface module with RJ-45 connector.
Figure A-4. IR-ETH Layout (UTP Option)
DIP Switch Settings
describes functions and default settings of the DIP switch SW-1 sections.
Table A-2. DIP Switch Settings
Section
Number
Name Description
Default
Setting
1
SQ/FD
ON – Full-duplex operation
OFF – Half-duplex operation
OFF
2
CMP
ON – Strips padding bits inserted in 64-byte frame
OFF – Transmits frames over WAN as is
OFF
3
FIL
ON – Passes only frames destined for another LAN
OFF – Disables LAN filter; passes all frames transparently
OFF
4
(nc)