beautypg.com

Displaying the vdsl performance diagnostics, Table 5-1, Lists the as – RAD Data comm 4-Wire Symmetrical VDSL Modem ASM-60 User Manual

Page 43: 2 displaying the vdsl performance diagnostics

background image

ASM-60 Installation and Operation Manual

Chapter 5 Diagnostics

Displaying the VDSL Performance Diagnostics

5-3

Table 5-1. ASM-60 Alarms

Number Terminal

Message Description

Severity

1 FPGA

DOWNLOAD

FAILED

Failure to download programming to the

ASM-60 FPGA microprocessor

Major

2

SELF TEST ERROR

A problem has been detected during the

device self-test

Major

3 DSP1

NOT

RESPONDING

No response from the ASM-60 digital

signal processor 1

Major

4 DSP2

NOT

RESPONDING

No response from the ASM-60 digital

signal processor 2

Major

5

DCD FAILED

Data Carrier Detect failure indicating

that ASM-60 cannot receive a carrier

signal from the other unit

Major

6

SYNC LOSS LINE A

Loss of synchronization on the 2-wire

line A

Major

7

SYNC LOSS LINE B

Loss of synchronization on the 2-wire

line B

Major

8

NO INTERFACE

No DTE interface is connected

Minor

9 LAN

NOT

CONNECTED

The Ethernet interface module is not
connected to the LAN

Minor

5.2 Displaying the VDSL Performance Diagnostics

ASM-60 has capabilities for collection of the VDSL performance diagnostics.

To display the VDSL diagnostics:
1. From the Main menu, type 2.

The Display menu appears.

2. From the Display menu, type 4.

The VDSL Performance screen appears (see

Figure 5-3

).

Table 5-2

lists the

ASM-60 performance monitoring parameters.

3. Type C to reset the performance registers, type R to monitor the VDSL

performance, type S to stop monitoring or press to exit.

Main Menu

2

Display

4

VDSL Performance