Table 5-1. ASM-60 Alarms
Number Terminal
Message Description
Severity
1 FPGA
DOWNLOAD
FAILED
Failure to download programming to the
ASM-60 FPGA microprocessor
Major
2
SELF TEST ERROR
A problem has been detected during the
device self-test
Major
3 DSP1
NOT
RESPONDING
No response from the ASM-60 digital
signal processor 1
Major
4 DSP2
NOT
RESPONDING
No response from the ASM-60 digital
signal processor 2
Major
5
DCD FAILED
Data Carrier Detect failure indicating
that ASM-60 cannot receive a carrier
signal from the other unit
Major
6
SYNC LOSS LINE A
Loss of synchronization on the 2-wire
line A
Major
7
SYNC LOSS LINE B
Loss of synchronization on the 2-wire
line B
Major
8
NO INTERFACE
No DTE interface is connected
Minor
9 LAN
NOT
CONNECTED
The Ethernet interface module is not
connected to the LAN
Minor
5.2 Displaying the VDSL Performance Diagnostics
ASM-60 has capabilities for collection of the VDSL performance diagnostics.
To display the VDSL diagnostics:
1. From the Main menu, type 2.
The Display menu appears.
2. From the Display menu, type 4.
The VDSL Performance screen appears (see
lists the
ASM-60 performance monitoring parameters.
3. Type C to reset the performance registers, type R to monitor the VDSL
performance, type S to stop monitoring or press
Main Menu
↓ 2
Display
↓ 4
VDSL Performance