Chapter 3

Configuration and Default Settings

NI VXIpc-882 User Manual

3-12

ni.com

Figure 3-9. Inverting the CLK10 Signal through MAX

CLK10 Termination

If the front panel SMB connector EXT CLK is configured as an input this
software setting can enable 50

Ω parallel termination. This setting can be

found in the hardware configuration panels in MAX, as shown in
Figure 3-9.

Trigger Input Termination

Optional software enabled 50

Ω parallel termination is available for the

front panel trigger input. This setting can be found in the hardware
configuration panels in MAX, as shown in Figure 3-9.

Note

Parallel termination is not necessary when the signal is driven by a 50

Ω source, such

as an NI VXIpc-882 controller.