Hot Surface
This icon denotes that the component may be hot. Touching this component
may result in bodily injury.
Safety Guidelines for Hazardous Voltages
If hazardous voltages are connected to the module, take the following
precautions. A hazardous voltage is a voltage greater than 42.4 V
pk
or
60 VDC to earth ground.
Caution
Ensure that hazardous voltage wiring is performed only by qualified personnel
adhering to local electrical standards.
Caution
Do not mix hazardous voltage circuits and human-accessible circuits on the same
module.
Caution
Make sure that the NI WLS/ENET-9163 carrier and circuits connected to the
module are properly insulated from human contact.
Caution
The NI WLS/ENET-9163 carriers provide no isolation, but some modules offer
isolation. Follow the safety guidelines for each module when using hazardous voltage.
Related Documentation
Each application software package and driver includes information about
writing applications for taking measurements and controlling measurement
devices. Check
ni.com/manuals
for the most recent hardware
documentation, and refer to Table 1 for a list of locations for driver and
application software documentation. The document location references in
this table assume you have NI-DAQmx 8.8 or later, and where applicable,
version 7.1 or later of the NI application software.